Optional) Configuring The Working Mode Of A Pon Interface - Huawei AR1200 series Configuration Manual

Hide thumbs Also See for AR1200 series:
Table of Contents

Advertisement

Huawei AR1200 Series Enterprise Routers
Configuration Guide - Interface Management
Pre-configuration Tasks
None.
Data Preparation
To configure attributes of an EPON interface, you need the following data.
No.
1
2
3
4
5
15.3.2 (Optional) Configuring the Working Mode of a PON
Interface
A PON interface must work in the same mode as the remote interface on the optical line terminal
(OLT).
Context
Working mode: When the AR1200 is connected to an EPON interface of an OLT, configure the
AR1200 to automatically determine the working mode according to the received optical signal,
or configure the PON interface connected to the OLT to work in EPON mode.
Issue 01 (2012-04-20)
or temperature is too high or too low. When this occurs, the AR1200 is forced offline and
services on the AR1200 are interrupted. By setting the alarm thresholds of these parameters,
you can monitor the status of the AR1200 on the NMS. When a parameter value exceeds
the alarm threshold, the AR1200 sends a trap to the NMS so that you can take measures
immediately.
Data
Number of the PON interface
NOTE
The value is in slot ID/subcard ID/interface sequence number format. The interface sequence
number is 0 or 1.
l When the sequence number of a PON interface is 0, services are configured on this interface.
l When the sequence number of a PON interface is 1, this interface functions as a backup
interface. In most cases, no service is configured on this interface.
(Optional) Working mode of the PON interface (EPON mode)
Laser working mode on the EPON interface
Authentication parameters of the EPON interface
Alarm thresholds of optical module parameters
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
15 PON Interface Configuration
159