Step 5 - Install Flue Hood; Step 6 - Trap Condensate Drain - Carrier WEATHERMAKER 48A2 Installation Instructions Manual

Single package gas heating/electric cooling rooftop units with comfortlink controls and puron refrigerant (r-410a)
Hide thumbs Also See for WEATHERMAKER 48A2:
Table of Contents

Advertisement

UNIT
MOTOR
SIZE
MOTOR
SHAFT DIA.
48A2,A3,
HP
(in.)
A4,A5
5
1.125
020
10
1.375
15
1.625
5
1.125
025
10
1.375
15
1.625
10
1.375
027
15
1.625
20
1.625
10
1.375
030
15
1.625
20
1.625
15
1.625
035
20
1.625
25
1.875
15
1.625
040
20
1.625
25
1.875
20
1.625
050
25
1.875
30
1.875
25
1.875
060
30
1.875
40
2.125
NOTES:
1. Motor shaft speed is 1750 rpm. The fan shaft diameter is 1
a48-8241
Fig. 12 — Air Distribution — Thru-the-Bottom
48A4 AND A5 UNITS — Remove shipping covers from
supply and return air openings. Attach field-supplied ductwork
to unit. Connect to the unit with a single duct for all supply
openings and with a single duct for all return openings.
Splitting of the airflow into branch ducts should not be done at
the unit. Sufficient duct length should be used prior to branch-
ing to ensure the air temperatures are well mixed within the
ductwork. See Fig. 7-9 for duct opening dimensions. Secure all
ducts to building structure. Air distribution is shown in Fig. 7-9
and Fig. 13.
Install accessory barometric relief or power exhaust in the
field-fabricated return ductwork. Refer to Step 10 — Position
Power Exhaust/Barometric Relief Damper Hood section on
page 30 for more information.
Table 6 — Evaporator Fan Motor Data
MOTOR
FAN
MOTOR
SHEAVE
SHAFT
SHEAVE
PITCH
SPEED
(P/N)
DIAMETER
(rpm)
(in.)
717
BK55
4.8
924
2BK50
4.4
1096
2B5V56
5.7
717
BK55
4.8
962
1B5V60
6.1
1106
2B5V54
5.5
848
2BK50
4.4
1059
2B5V56
4.9
1187
2B5V58
5.9
856
2BK50
4.4
1096
2B5V56
5.7
1187
2B5V58
5.9
1025
2B5V50
5.1
1147
2B5V56
5.7
1247
2B5V62
6.2
976
2B5V52
5.3
1050
2B5V56
5.7
1182
2B5V74
7.5
1050
2B5V56
5.7
1142
2B5V62
6.2
1234
2B5V66
6.7
1019
3B5V52
5.3
1086
3B5V58
5.9
1197
3B5V64
6.5
15
/
inches.
16
FAN
BUSHING
FAN
SHEAVE
DIAMETER
SHEAVE
PITCH
(in.)
(P/N)
DIAMETER
(in.)
NONE - 1.125
1B5V124
12.4
NONE - 1.375
2B5V86
8.6
B - 1.625
2B5V90
9.1
NONE - 1.125
1B5V124
12.4
H - 1.375
1B5V110
11.1
B - 1.625
2B5V86
8.7
NONE - 1.375
2B5V94
9.4
B - 1.625
2B5V90
8.1
B - 1.625
2B5V86
8.7
H - 1.375
2B5V94
9.0
B - 1.625
2B5V90
9.1
B - 1.625
2B5V86
8.7
B - 1.625
2B5V86
8.7
B - 1.625
2B5V86
8.7
B - 1.875
2B5V86
8.7
B - 1.625
2B5V94
9.5
B - 1.625
2B5V94
9.5
B - 1.875
2B5V110
11.1
B - 1.625
2B5V94
9.5
B - 1.875
2B5V94
9.5
B - 1.875
2B5V94
9.5
B - 1.875
3B5V90
9.1
B - 1.875
3B5V94
9.5
B - 2.125
3B5V94
9.5
2. All indoor fan motors meet the minimum efficiency requirements
as established by the Energy Policy Act of 1992 (EPACT), effective
October 24, 1997.
a48-8242
Fig. 13 — Air Distribution — Thru-the-Side
Step 5 — Install Flue Hood
48A2,A3,A4,A5020-050 UNITS — Flue hood is shipped in-
side gas section of unit. To install, secure flue hood to access
panel. See Fig. 14.
48A2,A3,A4,A5060 UNITS — Flue hood and wind baffle
are shipped inside gas section of unit. To install, secure flue
hood to access panel. Install the two pieces of the wind baffle
over the flue hood. See Fig. 15.
NOTE: When properly installed, flue hood will line up with
combustion fan housing. See Fig. 16.
Step 6 — Trap Condensate Drain —
for drain location. Condensate drain is open to atmosphere and
must be trapped. Install a trapped drain at the drain location.
One 1-in. female coupling is provided inside the unit evapora-
tor section for condensate drain connection. A trap at least 4-in.
deep must be used. See Fig. 17. Trap must be installed to pre-
vent freeze-up.
Condensate pans are sloped so that water will completely
drain from the condensate pan to comply with indoor air quali-
ty guidelines. The condensate drain pans are not insulated.
17
BUSHING
BELT
BELT
DIAMETER
(Quantity)
TENSION
(in.)
(P/N)
(lb at .25 in.)
B - 1.9375
BX56
8
B - 1.9375
(2) BX50
8
B - 1.9375
(2) 5VX530
9
B - 1.9375
BX56
8
B - 1.9375
5VX570
11
B - 1.9375
(2) 5VX530
9
B - 1.9375
(2) BX50
8
B - 1.9375
(2) 5VX530
10
B - 1.9375
(2) 5VX530
11
B - 1.9375
(2) BX50
8
B - 1.9375
(2) 5VX530
9
B - 1.9375
(2) 5VX530
11
B - 1.9375
(2) 5VX500
9
B - 1.9375
(2) 5VX530
10
B - 1.9375
(2) 5VX530
11
B - 1.9375
(2) 5VX530
10
B - 1.9375
(2) 5VX550
11
B - 1.9375
(2) 5VX590
11
B - 1.9375
(2) 5VX550
10
B - 1.9375
(2) 5VX570
11
B - 1.9375
(2) 5VX570
13
B - 1.9375
(3) 5VX530
12
B - 1.9375
(3) 5VX550
12
B - 1.9375
(3) 5VX570
14
See Fig. 4-9