7. If applied, connect DI/DO wires, 12V DC power, or audio wires to the terminal block.
7
1. The DO+ pin provides a 12V output, and the max. load is 50mA.
2. The max. voltage for DO- pins is 80VDC (External power).
In order to control AC devices, the following diagram can be taken into consideration.
This diagram uses a relay to control the ON/OFF condition of the AC device.
3. An external relay can be triggered by using the DO+ or by an external power source,
depending on the type of relay you use.
4. In case of using an individual relay (instead of using a relay module), for protection
against voltage or current spikes, a transient voltage suppression diode must be
connected in parallel with the inductive load.
BJT transistor
8 - User's Manual
3 4
1 2
DI-
VDC
DO+
Switch
DI+
DO-
NO
NC
Relay
9 10
7 8
5 6
External
power source
#
Name
1
EXT_MIC_N
2
EXT_MIC_P
3
Audio_out-
4
Audio_out+
5
DI-
6
DI+
7
DO-
8
DO+
9
12V DC-_IN
10 12V DC+_IN
AC
Source
External
device