EN 8
4.
Q522.2E LA

4. Mechanical Instructions

Index of this chapter:
4.1 Cable Dressing
4.2 Service Positions
4.3 Assy/Panel Removal ME8 Styling
4.4 Assy/Panel Removal MG8 Styling
4.5 Set Re-assembly
4.1
Cable Dressing
Tape the Control knob
cable to LCD Panel
Do not dress the control knob
cable too tight at IIR panel .
7x Tape
Figure 4-2 Mains inlet & left speaker cables 32"
Mechanical Instructions
Saddle for mains inlet,
Speaker, Tweeter
terminal and IR cable
dressing.
Tape the mains inlet cable to LCD
Panel away from the PSU edge
Tapes the terminal and IR
cable to LCD Panel
3x Saddle (M)
Figure 4-1 Cable dressing 32"
I_18010_006.eps
Notes:
Figures below can deviate slightly from the actual situation,
due to the different set executions.
Tape the LVDS cable to LCD
Panel.
Saddle for mains inlet cable dressing.
saddle position – away from PSU
area.
1x Saddle (S)
100608
Figure 4-3 LVDS & PSU_SSB cables 32"
Saddle for speaker ferrite ring
Saddle for 8P, 11P and Speaker
cable dressing.
Tapes the terminal cables
to LCD Panel
I_18010_005.eps
110608
I_18010_008.eps
100608