GE Simon XTi Installation Manual
Hide thumbs Also See for Simon XTi:

Advertisement

®
Simon
XTi Installation Guide
Content
Contact information......................................................... 1
Description ...................................................................... 1
Installation ....................................................................... 1
Connecting hardwired devices ....................................... 2
Wiring phone lines .......................................................... 3
Wiring the power transformer ......................................... 4
Resetting memory to factory defaults ............................. 4
Programming .................................................................. 5
Status & Settings screen ................................................ 5
Sensors ........................................................................... 7
Cleaning the touch screen ............................................ 10
Disposal ........................................................................ 10
Specifications ................................................................ 10
Regulatory information.................................................. 10

Contact information

www.utcfireandsecurity.com or www.interlogix.com
For customer support, see www.interlogix.com/contact
All trademarks are the property of their respective owners.
Interlogix is part of UTC Climate, Controls & Security, a unit of
United Technologies Corporation.
© 2016 United Technologies Corporation. All rights reserved

Description

This is the Installation Guide for the Simon® XTi system
(models 600-1054-95R-16 and 600-1054-95R-16-CN).
Table 1: Sensors and recommended sensor groups
Device
Part number
Indoor motion sensor
60-639-95R, 60-807-
b
95
Entry/exit door
60-362N-10-319.5
Interior door
60-362N-10-319.5
Door/Window sensor
60-362N-10-319.5
Smoke sensor
TX-6010-01-1
Glassbreak sensor
60-873-95
4-Button Key fob
600-1064-95R
Recommended
sensor group
15, 17, 18, 20, 28,
or 32
10
14
13
c
26
b
13
b
01
Device
Part number
Simon XT Talking
60-924-3-XT-2WTTS
Touch Screen
60-924-RF-TS
Simon XT Talking
60-924-3-XT
Touchpad
Carbon Monoxide alarm TX-6310-01-1
6520-95
a.
Not certified as a primary protection circuit for UL-listed
systems and is for supplementary use only.
b.
Has not been investigated by UL.
c.
Required for UL-listed residential fire alarm applications.
d.
The TWTTS has been verified for use by ETL. Neither this
device nor other devices that employ the UTCFS 80 Bit
Enhanced Protocol have been investigated for use by UL.
Note: These sensor groups are only recommendations. The installer
should choose the correct sensor group for the application.
CAUTION: Do not use outdoor motion sensors for
intrusion protection.
ATTENTION: N'utilisez pas des détecteurs de mouvement
extérieurs pour détecter les intrusions.
Safety information
IMPORTANT SAFETY INFORMATION. READ ENCLOSED
WARNINGS AND SAFETY INFORMATION.
WARNING: CHOKING HAZARD. The product accessory
bag contains items that could be choking hazards. Please keep
away from small children.
AVERTISSEMENT: Le sachet d'accessoires produit contient
des éléments qui pourraient être les dangers d'étouffement.
Veuillez garder hors de la portée des jeunes enfants.
WARNING:
Disconnect panel power before servicing.
AVERTISSEMENT: Débrancher l'alimentation du panneau
avant l'entretien.
CAUTION: Use static electricity precautions when handling
electronic components.
ATTENTION: Utiliser les précautions de l'électricite statique
lors de la manipulation des composants
Recommended
sensor group
b
00, 01, 04, 05, 06,
d
or 07
b
01
b
, 600-
34
b
électroniques.
P/N 466-5234 • REV A • 06APR16

Advertisement

Table of Contents
loading

Summary of Contents for GE Simon XTi

  • Page 1: Table Of Contents

    ® Simon XTi Installation Guide Content Device Part number Recommended sensor group Contact information............1 Simon XT Talking 60-924-3-XT-2WTTS 00, 01, 04, 05, 06, Description ..............1 Touch Screen 60-924-RF-TS or 07 Installation ............... 1 Simon XT Talking 60-924-3-XT Connecting hardwired devices ........2 Touchpad Wiring phone lines ............
  • Page 2: Installation

    Figure 2: Mounting holes Installation Panel location Locate the panel where alarm sounds can be heard and where the panel will be easily accessible for operation. Do not install the panel near a window or door where it can be reached easily by an intruder.
  • Page 3: Wiring Phone Lines

    Figure 4: Normally closed hardwired reed switches The HW1 I/O terminal is dual purpose and can be used for either siren or hardwired contact connections. The HW2 in terminal is an input only. Interior sirens From the factory, the HW1 I/O input (terminal 1) is set up for interior siren operation (status and alarm sounds).
  • Page 4: Wiring The Power Transformer

    cable black and white (or yellow) wires. Use weatherproof CAUTION: Do not connect the battery until you are ready wire connectors for these splices. to power up the panel. Connect the four-conductor cable green and red wires to ATTENTION: Ne branchez pas la batterie tant que vous n’êtes the Telco block TIP (+) and red to RING (-) posts.
  • Page 5: Programming

    sufficiently charged. After the initial charge, should the panel Item Description lose AC Power and experience a low battery These four icons depict the status of the sensors installed in your system. condition, the icon will appear and trouble beeps will sound A green check indicates sensors are closed or no unless silenced.
  • Page 6 Status & Settings Screen navigation Option How to view Programming Press the Access Codes icon to change existing Press the up/down arrows to scroll through the pages. or add new access codes. (See Table 3 below for Settings screen structure). Press the Security icon to turn downloader Press an icon to change the value of an option or enter a enable on/off and to set the account number.
  • Page 7: Sensors

    Option How to view Code Description Press the System Options icon to access the Installer Depending on how the access code is set, the default following system options: code installer code is 654321, 54321, 4321 (factory default), or 321. This code is limited to changing all but the following: •...
  • Page 8 Mounting Recommendations: Press Sensors. • Where possible, install sensors within 100 feet (30 m) of Press Learn Sensor. the receiver. While a transmitter and receiver combination Trip the sensor (see Table 6 above). The Edit Sensor may have an open-air range of 500 feet (152 m) or more, screen will appear.
  • Page 9 Access the System Test screen through the Programming Press Close repeatedly to exit. Screen, and then press OK. Sensor Test Failure Enter the dealer or installer code and press OK. If sirens do not beep when a sensor is tripped, use an RF Press Sensor Test.
  • Page 10: Cleaning The Touch Screen

    • Sensor testing should be done before and after permanent Power 9 VAC, 60 Hz, 25 VA transformer minimum mounting. Rechargeable battery: 6.0 VDC, 2.1 Ah NIMH. Maximum battery charging current is 120 mA. Comm Testing Once the battery reaches a low battery condition, a trouble signal will be annunciated, If Comm Test is not finished, it will continue to run even if you indicating that the battery may no longer...
  • Page 11 Household fire warning system (UL 985), basic system plus the Function Default setting Required setting following: Fire alarm verify • Wireless smoke sensor 60-848-02-95, TX-6010-01-1 Duress/panic code Disabled Disabled learned into sensor group 26. Cross zone Disabled Disabled for zones •...
  • Page 12 UL Canada listed installations Warranty Information MANUFACTURER HEREBY DISCLAIMS ALL WARRANTIES This section describes the requirements for CUL (UL Canada) AND REPRESENTATIONS, WHETHER EXPRESS, IMPLIED, listed installations. STATUTORY OR OTHERWISE INCLUDING (BUT NOT LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY Canadian standards CSA certified accessories: OR FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO ITS CONCORD 4 PRODUCTS AND RELATED •...