Wiring Diagrams - Bryant 189BNV EVOLUTION Service Manual

V variable speed air conditioner/v variable speed heat pump
Hide thumbs Also See for 189BNV EVOLUTION:
Table of Contents

Advertisement

WIRING DIAGRAMS - - 189BNV
W
BLK
CHOKE
1
+
LD1
DC
DC FAN
F L1 L2
FUSE 3 AMP
120
30
60
90
J2
FORCED
DEFROST
YEL
BLK
PL18
LVCH
GRN
TB
21
23
L1
L2
208/230 1Ø POWER SUPPLY
Fig. 43 – 189BNV WIRING DIAGRAM - - Sizes 13 and 24B
CONNECTION DIAGRAM
OFM
COMP
(R)
U
V
(C)
W
RED
U
(S)
V
YEL
YEL
RED
BLK
CHOKE
RED
BLK
YEL
4
-
DC
2
U
V
W
MOTOR & COMPRESSOR
CONTROL SECTION
HPS
BLU
BLU
MOTOR CONTROL COMM HEADER
HP CONTROL COMM HEADER
RVS
PEV
PL10
1
SW2
60
30
BLU BLU
1 2
PL19
SPT
STATUS COMM
1
PEV
PL17
AIR CONDITIONER
OST
CONTROL SECTION
1
PL16
ODT
MODEL
1
PL15
24V
UTIL
C
R
Y
1
Y
2
W
O
OCT
OAT
1
BLK
BRN
BRN
BLK
UTILITY INTERFACE
CHOKE
OCT
OAT
EQUIP GND
Fig. 44 – 189BNV WIRING DIAGRAM - - Sizes 25, 36, 37, 48, 49, 60
UNIT OPERATION
This control board contains a 3.5 minute short cycle protector. A 3.5 minute delay will occur between
Compressor off/on cycles. To bypass delay, short forced defrost pins for 1 second then release.
However, there is an additional 2.5 minutes delay upon expiration of the 3.5 minute short cycle delay to
ensure the high and low side pressures are equalized. This is important for long term rotary compressor
reliability. It is a delay that cannot and must not be bypassed. The internal crankcase heater is energized
during off cycle as needed.
NOTES:
1. To Be Wired In Accordance With National Electric Code (N.E.C.) And Local Codes.
HPS
2. Use Copper Conductors Only. Use Conductors Suitable For At Least 75ºC (167ºF).
BLU/PNK
3. Two Wire A and B Required For Communication. If Outdoor Unit Improperly
BLU/PNK
Grounded, Connect Indoor Ground To "C" Terminal.
4. If Any Of The Original Wire, As Supplied, Must Be Replaced, Use The Same Or
Equivalent Wire.
5. Check All Electrical Connections Inside Control Box For Tightness.
6. Do Not Attempt To Operate Unit Until Service Valves Have Been Opened.
7. If Communicating, Must Use With Infinity or Evolution User Interface Listed In
Pre-sale Literature Only.
8. For Non-Communicating Thermostats, 24VAC To Be Provided To R Connection.
9. N.E.C. class 2, 24 V circuit, min. 40 VA required, 60 VA on units installed with LLS.
-LEGEND-
SPT
FACTORY POWER WIRING
BLK
+
FIELD POWER WIRING
WHT
-
FACTORY CONTROL WIRING
RED
FIELD CONTROL WIRING
COMPONENT CONNECTION
BLK
JUNCTION
BLK
FIELD SPLICE
OST
PLUG CONNECTION
BLK
SYSTEM COMMUNICATION
COMM
COMPRESSOR
COMP
BLK
LD1
HIGH VOLTAGE INDICATOR LED
ODT
HPS
HIGH PRESSURE SWITCH
LOW VOLTAGE CHOKE HARNESS
LVCH
* MAY BE FACTORY OR FIELD INSTALLED
MODEL PLUG CHART
MODEL MODEL
PIN RESISTANCE (K
SIZE
PLUG
HK70EZ
1 - 4 (R1)
2 - 3 (R2)
25
011
5.1K
150K
36
012
5.1K
180K
025
11K
091K
37
48
013
5.1K
220K
49
027
11K
150K
60
014
5.1K
270K
34
MODEL PLUG
MODEL
OUTDOOR AIR THERMISTOR
OAT
OCT
OUTDOOR COIL THERMISTOR
ODT
OUTDOOR DISCHARGE THERMISTOR
OUTDOOR FAN MOTOR
OFM
OUTDOOR SUCTION THERMISTOR
OST
PRESSURE EQUALIZER VALVE
PEV
SUCTION PRESSURE
SPT
TRANSDUCER
STATUS
SYSTEM FUNCTION LIGHT
DEFROST TIME SELECT
SW2
TERMINAL BLOCK
TB
UTILITY CURTAILMENT
UTIL
24 VOLTS DC
24V
)
340613-101 REV. C