2. DIMENSIONS AND TECHNICAL DATA

2.01 Dimensions and technical data (fig. 2 - tab. 1)
400
B
Key
a1 Flow 11/2"
a2 Return 11/2"
a3 Boiler drain 11/2"
Heat and
Heat and
D.H.W.
D.H.W.
Model
(gross)
(net)
gas
gas+oil
Max.
Max.
GN1 N 02
28,6
25,8
GN1 N 03
43
38,7
GN1 N 04
57,3
51,6
GN1 N 05
71,6
64,5
GN1 N 06
86,1
77,5
GN1 N 07
100,4
90,4
GN1 N 08
114,7
103,3
Working
Model
pressure
bar
GN1 N 02
4
GN1 N 03
4
GN1 N 04
4
GN1 N 05
4
GN1 N 06
4
GN1 N 07
4
GN1 N 08
4
N.B.: - Max. water temperature for the heating system is 90° C. - Min. water temperature for the heating system is
45° C.
Supplied By www.heating spares.co Tel. 0161 620 6677
Heat and
Heat and
Heat and
D.H.W.
D.H.W.
D.H.W.
(gross)
output
gas
gas+oil
Max.
Min.
23,3
18,2
34,9
18,2
46,5
39,3
58,1
49,1
69,8
59,1
81,4
68,8
93,0
78,6
A
B
Ø
300
105
130
400
105
130
500
105
130
600
105
180
700
125
180
800
125
180
900
125
180
A
Fig. 2
Heat and
D.H.W.
(net)
output
element
Min.
Min.
16,4
15,0
2
16,4
15,0
3
35,4
32,5
4
44,2
40,5
5
53,2
48,8
6
62,0
57,0
7
70,8
65,0
8
Combustion
Combustion
chamber
chamber
load loss
volume
∆p mbar
3
dm
0,2
12,09
0,2
20,15
0,2
28,21
0,2
36,27
0,2
52,39
0,2
60,45
0,2
68,51
a1
1" 1/2
1/2"
85
a2
a3
Combustion
Combustion
Water
chamber
chamber
capacity
lenght
dimension
3
dm
mm
Ømm
11
286
260x310
14
386
260x310
17
486
260x310
20
586
260x310
23
686
260x310
26
786
260x310
29
886
260x310
Water
Weight
load losses
of unit
∆t
∆t
10
20
1
-
1,8
-
4,2
1
7,2
1,6
11
2,3
15
3,3
20
4,5
kg.
75
100
125
150
175
200
225
5