Note : The method of manual override can either be selected to operate from the valet switch or operate as custom code. Be
certain to place a check mark indicating the method used in the box located on the last page of the owner's manual.
Dip Switch Selectable Features :
Switch Number
Dip Switch 1
Dip Switch 2
Note : When both Passive Arming and Voltage Sensing are selected, you must hardwire the driver's door pin switch in order to
begin the passive arming sequence.
RF Programmable Features :
Feature Selection
First
Second
Third
Fourth
Fifth
Sixth
To program these selectable features;
First
Second
Third
Fourth
Fifth
Sixth
Note : Once you enter the feature programming mode, do not allow more than 15 seconds to pass between steps, or the
programming will be terminated.
SELECTABLE FEATURES
ON Position
Custom Code Override
Voltage Sense
1 Chirp
1 Second Door Locks
Auto Lock On
Auto Unlock On
Headlight Output On
Passive Door Locks
Passive Arming
Action
Turn ignition on
Flip valet switch on then off 3 times
Within 3 seconds, turn ignition Off
Then On
Press the Lock/Unlock button to change
or
Flip valet switch on then off
Press the Lock/Unlock button to change
or
Flip valet switch on then off
Press the Lock/Unlock button to change
or
Flip valet switch on then off
Press the Lock/Unlock button to change
or
Flip valet switch on then off
Press the Lock/Unlock button to change
or
Flip valet switch on then off
Press the Lock/Unlock button to change
or
Flip valet switch on then off
or
Turn ignition key off
Model PRO 9549UG
OFF Position
Valet Switch Override
Hardwire
2 Chirps
3.5 Second Door Locks
Auto Lock Off
Auto Unlock Off
Headlight Output Off
Active Door Locks
Active Arming
System Response
No response
1 Chirp - LED 1 flash
Short chirp, then long chirp
1 chirp = 1 second door locks
2 chirps = 3.5 second door locks
2 chirps = auto locks off
1 chirp = auto locks on
2 chirps = auto unlock off
1 chirp = auto unlock on
1 chirp = headlight output on
2 chirps = headlight output off
1 chirp = passive locks
2 chirps = active locks
1 chirp = passive arming
2 chirps = active arming
Exit program mode
Exit program mode
Page 1
Installation Manual
Factory Default
Valet Switch Override
Voltage Sense
Default
1 Second
Auto Lock Off
Auto Unlock Off
Headlight On
Passive Locks
Active Arming

Advertisement

loading

Summary of Contents for Audiovox UltraGuard PRO 9549UG

  • Page 1 2 Chirps 3.5 Second Door Locks Auto Lock Off Auto Unlock Off Headlight Output Off Active Door Locks Active Arming Page 1 Model PRO 9549UG Installation Manual Factory Default Valet Switch Override Voltage Sense Default 1 Second Auto Lock Off...
  • Page 2 INSTALLATION OF MAJOR COMPONENTS Control Module : Select a mounitng location inside the passenger compartment ( up behind the dash ), and secure using the two screws provided. The control module can also be secured in place using cable ties. Do not mount the control module in the engine compartment, as it is not waterproof.
  • Page 3 When installing this system into vehicles with electronic “ after fans “, it is recommended you disable the voltage sense circuit. In voltage sensing applications, the closer to the battery that the red wire is connected, the less sensitive the voltage sense circuitry will be.
  • Page 4 Mini 10 Pin Edge Connector : Light Green Wire : ( - ) Instant Trigger Zone 1 This is an instant on ground trigger wire. This wire ( zone ) should be reserved for connection to optional ground output trigger devices such as motion and / or shock impact sensors. White w/ Blue Trace Wire : Headlight Output - Arm &...
  • Page 5 This wire provides an immediate ground signal, and stays at ground for up to 8 seconds as long as the button(s) on the keychain transmitter remain pressed. WARNING ! Connecting the dark green w/ black trace wire to the high current switched output of trunk release circuits will damage the control module.
  • Page 6: Completing The Installation

    5 Wire Alternating Door Lock Circuits : In this application, it is necessary to cut the existing door lock by - pass wires. These wires run from the master door lock switch to the slave door lock switch, and then on to the door lock motors. Cut the existing lock wire, and connect the yellow wire to the slave switch or motor side of the cut wire.
  • Page 7: Trunk Release

    SIREN GREEN w/WHITE ENTRY ILLUMINATION Connect to +12 VDC Battery for Positive Switched Dome Light or Chassis Ground for Negative Switched Dome Light EXISTING DOOR PIN SWITCH DOME LIGHT GREEN w/WHITE GROUND SOURCE Connect to Vehicle's Chassis TRUNK RELEASE Connect to +12 VDC Battery for Positive Switched Trunk Release Chassis Ground for Negative Switched Trunk Release...
  • Page 8 DARK GREEN EXISTING NEGATIVE SWITCHING EXISTING DOOR PIN SWITCH (GM TYPE) DOME LIGHT EXISTING DOME LIGHT UltraGuard Security Systems, 15600 Roscoe Blvd., Van Nuys, CA 91406 PRO 9549UG CONTROL MODULE WHITE w/BLUE BROWN PURPLE VALET SWITCH GREY BLACK 2 STEP UNLOCK...