8. Troubleshooting
8.1 Indoor Unit Error Display
Operation lamp
Timer lamp
☆ 1 time
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 7 times
☆ 1 times
☆ 2 times
☆ 3 times
☆ 4 times
☆ 5 times
☆ 6 times
☆ 1 times
☆ 2 times
☆ 5 times
Display
LED STATUS
Indoor unit EEPROM parameter error
X
E0
Indoor / outdoor units communication error
X
E1
X
E2
Zero-crossing signal detection error
X
E3
Indoor fan speed has been out of control
Open circuit or short circuit of indoor room temperature T1
X
E4
sensor
Open circuit or short circuit of evaporator coil temperature T2
X
E5
sensor
X
EC
Refrigerant Leakage Detection
O
F0
Overload current protection
Open circuit or short circuit of outdoor ambient T4 temperature
O
F1
sensor
Open circuit or short circuit of condenser coil temperature T3
O
F2
sensor
Open circuit or short circuit of compressor discharge T5
O
F3
temperature sensor
O
F4
Outdoor unit EEPROM parameter error
O
F5
Outdoor fan speed has been out of control
☆
P0
IPM malfunction or IGBT over-strong current protection
☆
P1
Over voltage or over low voltage protection
☆
P4
Inverter compressor drive error
O(light)
☆(flash)
X(off)
39