Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Mode

Fan speed

level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
SUL/SL-
W2
SUL
W1
Mode
Fan speed
level
Cool
Heat
WF
UH
WE
UH
H
WD
H
M+
WC
M+
WB
M
WA
M
W9
L+
W8
L+
L
W7
L
L-
W6
L-
W5
UL
UL
W4
W3
SUL
SUL/SL-
W2
SUL
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WC)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4 : Fan speed = (M + –L) x 2/4 + L
*4
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W7)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-07BKV-E
Cooling
Fan speed Air flow rate
Fan speed Air flow rate
DRY
3
(rpm)
(m
/hr)
(rpm)
1080
540
1080
1080
540
1080
UH
1050
520
1030
H
1000
490
940
M+
910
430
850
M
820
370
850
820
370
730
L+
710
300
620
600
230
580
L
570
220
580
L-
550
200
550
UL
550
200
550
540
190
520
520
180
520
500
170
500
RAS-13BKV-E
Cooling
Fan speed Air flow rate Fan speed Air flow rate
DRY
3
(rpm)
(m
/hr)
(rpm)
1200
620
1200
1200
620
1200
UH
1170
600
1080
H
1120
560
1020
M+
1010
500
960
M
900
420
960
900
420
840
L+
770
340
720
640
250
660
L
620
240
660
L-
600
230
600
UL
600
230
600
560
180
520
520
180
520
500
170
500
(Fig. 1)
Fan speed
W7
(L + M) / 2
WA
(M + H) / 2
WD
(Fig. 2)
RAS-10BKV-E
Heating
Cooling
Fan speed Air flow rate
3
3
(m
/hr)
(rpm)
(m
/hr)
540
1110
580
540
1110
580
510
1080
530
450
1030
510
380
940
450
380
850
390
310
850
390
240
730
310
225
620
240
225
590
230
200
570
220
200
570
220
180
550
200
180
520
180
170
500
170
Heating
3
(m
/hr)
620
620
530
500
470
470
380
305
265
265
230
230
180
180
170
- 29 -
FILE NO. SVM-16003
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
Heating
Fan speed Air flow rate
3
(rpm)
(m
/hr)
1110
580
1110
580
1060
525
870
400
870
400
750
325
750
325
640
250
600
230
600
230
570
220
570
220
520
180
520
180
500
170