Specifications
Table 9 Environmental
Specifications
Climatic Environment
Temperature
Relative humidity
Altitude
Vibration and Shock
Operational Shock
Operational Vibration
Shipping and Storage
Acoustic
Acoustic output
Agency Approvals
Safety
Emissions
DXi6700, DXi6701, and DXi6702 Specifications
Table 9
provides various DXi6700, DXi6701, and DXi6702 environmental specifications.
Operating
Shipping and storage
Operating
Shipping and storage
Operating
Shipping and storage
Peak Acceleration
Duration
Wave Shape
Mode
Frequency Range
Amplitude
Rate/Duration
Application
Mode
Frequency Range
Amplitude
Rate/Duration
Operating
IEC 60950-1, CSA 60950-1-03/UL 60950-1
EN55022 Class A, FCC Part 15 Class A, ICES-003 Class A, VCCI Class A, CISPR 22 Class A,
CNS13438 Class A, KN22 Class A
DXi6700/DXi6701/DXi6702
10° to 35°C (50° to 95°F) up to 3048m (10,000 ft)
–20° to 60°C (–4° to 140°F) up 12,000m (39,370 ft)
20% to 80% (non-condensing)
5% to 95% (non-condensing)
–30m to 3048 m (–100 to 10,000 ft)
–30m to 12,000 m (–100 to 39,370 ft)
3G
8 milliseconds
½ Sine
Swept frequency
20Hz–300Hz
0.25G
0.75 octaves/minute
X, Y, and Z axes
Random Vibration
4Hz–300Hz
0.96 Grms
(PSD can be provided) 30 minutes X, Y, Z axes
< 67 dBA at 1 meter, room temperature (20C)