Applying Vibrato (Pitch Modulation); Control The Stereo Location (Pan); If The Sound Does Not Stop; Stopping The Sound From An External Midi Device - Korg Prophecy Basic Manual

Multi oscillator synthesis system
Hide thumbs Also See for Prophecy:
Table of Contents

Advertisement

38
5.9 Applying vibrato (pitch modulation}*
2
If you have assigned Pitch Modulation (control change #01) to a controller such as Wheel1--3, the
Ribbon Controller, or a connected pedal switch, operating that controller will control the vibrato effect.
At the same time, Pitch Modulation Depth messages [Bn,01,vv] (control change #01) will be
transmitted. (vv: value).
If
you want to control pitch modulation from an external device using control change messages, set the
Global section page GLB-11 [MIDI Control Change] control change #01 Receive parameter to "ENBL"
or "INTP."
5.10
Control the stereo location (pan}*
2
These settings are made in Edit mode Effect section page FX-4 [Pan
&
Output Level]. If you wish to
control this using the MIDI Pan message [Bn,OA,vv] (control change #10) (vv: value), make settings in Edit
mode Global section page GLB-11 [MIDI ControlChange] to set reception for Control Change #10 to
"ENBL'' or "INTP".
'
2
The Prophecy allows you to specify how the built-in controllers (Wheel 1/2/3, Ribbon Controller, etc.) and
MIDI control messages (Control Change #00-#95, Pitch Bend, etc.) that are transmitted and received will
correspond to the parameters of the tone generator (i.e., those parameters for which a modulation source can be
selected). This means that the examples given
in
5.5-5.10 above are only example of one particular setting, and
are not fixed. (For the relation between controllers, messages and parameters, refer to the diagram
in
Global
section GLB-9 [MIDI Pitch Bend].
5.11
If the sound does not stop
If due to some problem a note becomes "stuck" and the sound does not stop, you can re-select a
program to stop the sound.
If
the Prophecy is receiving MIDI messages from a MIDI device that transmits Active Sensing messages
[FE], and
if
for some reason no MIDI messages are received for a certain interval, the sound will
automatically be halted.
5.12
Stopping
the sound from an external
MIDI device
When an All Note Off message [Bn,7B,OOJ (control change #123) is received, the Prophecy will turn off
all its keys.
When an All Sound Off message [Bn,78,00J (control change #120) is received, the Prophecy will stop
sounding. The difference between these two messages is that with All Note Off, the decay of the note
will remain, while with All Sound Off, the note will stop immediately. However these messages are
intended only for emergencies, and should not be used during normal playing.
5.13
To reset all controllers on a given channel
When an All Controller Reset message [Bn,79,00] (control change #121) is received, all controllers will
be reset.
However this message i:; intended only for emergencies, and should not be used during normal
playing.