2.10 Specification - Bosch OptiFlow Professional GWH12 1 CTD E23 F3 OL Installation Manual

Gas continuous flow water heaters
Hide thumbs Also See for OptiFlow Professional GWH12 1 CTD E23 F3 OL:
Table of Contents

Advertisement

2.10 Specification

Technical features
Performance
Nominal gas consumption
Minimum gas consumption
Efficiency at 100% of nominal load
Gas supply data
Gas supply pressure (flowing)
Natural gas (when operating)
Universal LP gas (when operating)
Water supply data
Maximum permissible pressure (static)
Minimum operating pressure
Minimum water flow
Maximum flow, corresponding to a temperature increase of 25 °C
Maximum inlet temperature
Electrical circuit
Power supply voltage
Frequency
Maximum power consumption
Appliance enclosure rating
General data
Weight (unpacked)
Height
Width
Depth
Table 5
OptiFlow Professional
Product details | 9
Units
GWH12
MJ/h
90.0
MJ/h
11.9
%
82.4
kPa
1.13
kPa
2.75
kPa
1000
kPa
100
l/min
2.2
l/min
12.0
°C
80
V
230
Hz
50
W
228
IPX5D
kg
10
mm
570
mm
300
mm
170
6 720 810 559 (2016/06)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents