Refrigerant Recovery (During Pump-Down Operation) Of The Troubled Outdoor Unit; (In Case Of Trouble Of Follower Unit) - Toshiba MMY-MAP1006FT8(J)P-E Service Manual

Super heat recovery multi-e (multi type) outdoor unit
Hide thumbs Also See for MMY-MAP1006FT8(J)P-E:
Table of Contents

Advertisement

4-9. Refrigerant recovery (during pump-down operation) of the troubled outdoor unit)

(In case of trouble of follower unit)

Outdoor header unit (MMY-MAP1806FT*)
SV52
SV
PMV1
SV12
SV
PMV4
TE2
SV
SV
SV5
SV
TL1
SV6
Fusible
plug
FP
SV3D
SV
Liquid tank
SV41
SV
TD1
SV14
Check joint
SV3E
(Liquid pipe)
PMV
TCS
SVD
SVDD
TC2 TCJ
Cooling
Header outdoor unit
4-Way valve
OFF
SV4(n)
OFF(*1)
SV51
ON
SV52
OFF
SV6
Control
SV11
OFF
SV12
OFF(*2)
SV14
OFF
Outdoor Fan
(*1) SV4(n) of stopped compressor (n) = ON
(*2) It may be controlled.
(*3) In defrost mode, PMV4 and PMV FS also open.
The outdoor unit which communication line between indoor and outdoor is connected is the "Header unit".
Other outdoor units are called "Follower units".
Fan
Fan
FM
FM
Fan motor
Fan motor
Right side
TO
Main heat exchanger
Right side sub heat exchanger 2
Right side sub heat exchanger 1
Left side
Main heat exchanger
TE1
Left side sub heat exchanger 2
Left side sub heat exchanger 1
4-way
SV11
valve
Check joint (High-pressure)
High-pressure sensor
Accumlator
SV2
SV
Oil
separator
SV42
SV3C
SV
TD2
TK4
High
pressure
High
SW
pressure
SW
Comp1
Comp2
TK1
TK2
Oil header
TK5
SV3A
SV3B
SV
Balance pipe
Liquid pipe
Discharge gas pipe
Suction gas pipe
PMV
TCS
SVS
SVD
SVSS
SVDD
TC1
TC2
TCJ
Cooling
SV3A
Control
4-Way valve
SV3B
Control
SV4(n)
SV3C
Control
SV51
SV3D
Control
SV52
SV3E
ON
SV6
PMV1
Control
SV11
PMV4
Control
SV12
Control
SV14
High-pressure gas refrigerant
Condensed liquid refrigerant
Evaporative gas refrigerant (Low pressure)
( 32 HP system described in the example of ( 18HP + 14HP ))
Outdoor follower unit (MMY-MAP1406FT*)
Trouble
SV52
SV
PMV1
PMV4
TE2
TS1
TL1
Low-pressure sensor
Check joint
可溶栓
(Low-pressure)
FP
TS2
Liquid tank
(SV14)
Check joint
(Liquid pipe)
PMV
TCS
SVS
SVD
SVSS
SVSS
SVDD
TC1
TC2
TCJ
Cooling
Trouble outdoor unit
OFF
SV3A
Control
OFF(*1)
SV3B
Control
ON
SV3C
Control
OFF
SV3D
Control
Control
SV3E
ON
OFF
PMV1
Control
OFF
PMV4
Close(*3)
OFF
Outdoor Fan
Control
− 66 −
Fan
FM
Fan motor
Right side
Main heat exchanger
Right side sub heat exchanger
Left side
Main heat exchanger
TE1
Left side sub heat exchanger
SV
SV11
SV
SV5
SV
SV6
Check joint (High-pressure)
High-pressure sensor
SV2
SV3D
SV
Oil
SV
separator
SV41
SV42
SV3C
SV
SV
TD1
TD2
TK4
Comp1
Comp2
TK1
TK2
Oil header
SV3E
TK5
SV3A
SV3B
SV
Balance pipe packed valve = Open full
Low pressure gas pipe service valve = Open full
⇒ Liquid pipe 10 minutes after operation = Close full
Liquid side service valve, dischage pipe service valve = Close full
PMV
TCS
SVS
SVS
SVD
SVSS
SVDD
TC1
TC2 TCJ
Cooling
FS unit / Indoor unit
Cooling thermo ON
SVD
OFF
SVS
ON
SVDD
OFF
SVSS
ON
PMV FS
Close(*3)
PMV indoor
Control
Pressure circuit (High-pressure refrigerant)
Low-pressure circuit (Refrigerant recovery line)
TO
4-way
valve
TS1
Low-pressure sensor
Check joint
(Low-pressure)
TS2
Accumlator
0
TC1