Consider installing an air cleaner with deep-pleated media filter at the time of furnace installation. A deep-pleated filter with a MERV
rating of 8 (minimum) will often provide better filtration to protect equipment and the air distribution system than a standard 1" filter
and often has lower static pressure loss than a 1" filter. Also a deep-pleated filter will typically require less frequent replacement
intervals. Avoid using highly restrictive 1" filters which produce static pressure loss greater than .25" W.C. In some installations the
minimum filter size required (consult filter sizing chart) will not lend itself to a filter installation on the side of the furnace. The
installation of a centrally installed air cleaner cabinet or a return duct filter installation may offer more practicality.
Clean Comfort™ brand MERV 11 air cleaners have 5¼" media filters and are available in the following configurations. Consult your
distributor for information on our complete line of IAQ Clean Comfort™ products.
Air cleaner installation location Maximum Heating Airflow Filter (Media) Dimensions Part Number
Si de or bottom return
Si de or bottom return
Si de or bottom return
Si de or bottom return
Si de return
(for 2 s epa ra te returns )
Si de return (Ri ght a ngl e)
Bottom return (pl a tform)
Bottom return (pl a tform)
AM11-5
Family
H
I
ORIZONTAL
NSTALLATIONS
Filters must be installed in either the central return register or in
the return air duct work.
S
O
(I
EQUENCE OF
PERATION
NTEGRATED
Refer to Timing Charts for sequencing.
NOTE: Dip switch positions referenced in this section applies to
(GME8, AMEH8, GDH8, ADSH8 & (A/G)MH8 MODELS ONLY).
P
U
OWER
P
115 VAC power applied to furnace.
1200 CFM
1600 CFM
1600 CFM
2000 CFM
2 X 1600 CFM
2000 CFM
2000 CFM
2000 CFM
AM11-5RA
Family
I
C
)
GNITION
ONTROL
16 i n X 20 i n x 5¼"
16 i n X 25 i n x 5¼"
20 i n X 20 i n x 5¼"
20 i n X 25 i n x 5¼"
2, 16 i n X 25 i n x 5¼"
20 i n X 25 i n x 5¼"
20 i n X 25 i n x 5¼"
20 i n X 25 i n x 5¼"
Integrated ignition control performs internal checks.
Integrated ignition LED will light.
Integrated ignition control monitors safety circuits
continuously.
Furnace awaits call from thermostat.
21
Air
Cleaner
Family
AM11-1620-5
AM11-1625-5
AM11-5
AM11-2020-5
AM11-2025-5
AM11-3225-5
AM11-3225
AM11-2025-5RA AM11-5RA
AM11-2832-5PP
AM11-5PP
AM11-2843-5PP
AM11-5PP
Family

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mh8Ms8Gd8Gdh8Gds8Ghs8 ... Show all

Table of Contents