To Connect The Remote Outdoor Sensor; To Connect The User Interface - Daikin EGSQH10S18AA9W Installer's Reference Manual

Altherma ground source heat pump
Hide thumbs Also See for EGSQH10S18AA9W:
Table of Contents

Advertisement

X2M
X5M
30
X6YB
X6Y X6YA
Legend: see illustration below.
In case of preferential kWh rate power supply
Connect X6Y to X6YB.
S1S
L
c
30 31
X2M
29
3 4
X5M
X6Y
X6YB
X6YA
a
Main power supply
b
Normal kWh rate power supply
c
Preferential power supply contact
2 Fix the cable with cable ties to the cable tie mountings.
INFORMATION
In case of preferential kWh rate power supply, connect
X6Y to X6YB. The necessity of separate normal kWh rate
power supply to indoor unit (b) X2M30/31 depends on the
type of preferential kWh rate power supply.
Separate connection to the indoor unit is required:
▪ if preferential kWh rate power supply is interrupted
when active, OR
▪ if no power consumption of the indoor unit is allowed at
the preferential kWh rate power supply when active.
7.6.7

To connect the remote outdoor sensor

The remote outdoor sensor (delivered as accessory) measures the
outdoor ambient temperature.
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351748-1D – 2016.02
X1A
X19A
31
a
X1M
N
L3
L2
L1
N
b
X1A
X19A
34
a
X1M
N
L3
L2
L1
INFORMATION
If the desired leaving water temperature is weather
dependent, the full time outdoor temperature measurement
is important.
1 Connect the external temperature sensor cable to the indoor
unit.
X5M
X2M
11
12
10
2 Fix the cable with cable ties to the cable tie mountings.
3 Install the remote outdoor sensor outside as described in the
installation manual of the sensor (delivered as accessory).
7.6.8

To connect the user interface

▪ If you use 1 user interface, you can install it at the indoor unit (for
control close to the indoor unit), or in the room (when used as
room thermostat).
▪ If you use 2 user interfaces, you can install 1 user interface at the
indoor unit (for control close to the indoor unit) + 1 user interface
in the room (used as room thermostat).
The procedure differs slightly depending on where you install the
user interface.
#
At the indoor unit
1
Connect the user interface cable to the indoor unit.
Fix the cable with cable ties to the cable tie mountings.
X5M
1 2
a Main user interface
b Optional user interface
7 Installation
In the room
a
b
X2M
(a)
Installer reference guide
31

Advertisement

Table of Contents
loading