DuctinG matErials:
For best performance, this dryer should be vented with 4" diameter all rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-
rigid) ducting can be used (Kit WX08X10077). In special installations, it may be
necessary to connect the dryer to the house vent using a flexible metal (foil-type) duct.
A UL-listed flexible metal (foil-type) duct may be used ONLY in installations where
rigid metal or flexible metal (semi-rigid) ducting cannot be used AND where a 4"
diameter can be maintained throughout the entire length of the transition duct. Please
see installation instruction packed with your dryer for complete instructions when using
flexible metal (foil type) ducting.

Exhaust lEnGth calculatiOn:

1.
Determine the number of 90° turns needed for your installation. If you exhaust to
the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be
tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45° turns
within the duct length should be treated as a 90° elbow. A turn over 45° should be
treated as a 90° elbow.
Dryers must be exhausted to the outside.
cautiOn: For personal safety do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust into
a common duct or plenum with a kitchen exhaust, since the combination of lint and
grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts,
bird nesting, etc. The wall cap must also be located at least 12" above the ground or any
other obstruction with the opening pointed down.
fOr mOrE infOrmatiOn On vEntinG kits anD accEssOriEs, plEasE
call 1-800-GE-carEs.
For answers to your Monogram,
GE Profile
®
or GE
appliance questions, visit our website
®
at geappliances.com or call GE Answer Center
service, 800.626.2000.
GE Dryer Vent
DryEr ExhaustinG infOrmatiOn—
usE mEtal Duct Only vErtical anD
hOrizOntal DuctinG
A
A
4
Domestic dryer models
GE Frontload Long Vent 7.0
cu. ft. capacity electric dryer
(GFDL)
Long Vent 6.0 - 8.0 cu. ft.
capacity electric & gas dryers
(GTDL and GTV)
Long Vent 7.0 cu. ft. capacity
electric & gas (GTD42, GTD45,
GTD65, GTX42 and GTX60)
All 6.0 - 8.3 cu. ft. capacity
models electric and gas dryers
(GFDS, GFDR, GFDN, GTDS,
GTDN, GHDN, GHDS, GTDP,
GLDP, GTD, HTDP, HTDX)
DCVH480
All 3.6 cu. ft. (DSKS, DSKP)
electric dryers
Laundry Center GUD27
Laundry Center GUD24
®
BEst pErfOrmancE
Maximum length
of 4" dia rigid
A
4
metal duct
B
Exhaust hood type
Number
A
2-1/2
of 90°
4"
B
turns
opening
0
200 ft.
2-1/2
1
185 ft.
2
175 ft.
3
165 ft.
4
155 ft.
5
145 ft.
0
150 ft.
1
135 ft.
2
125 ft.
3
115 ft.
4
105 ft.
5
95 ft.
0
120 ft.
1
100 ft.
2
85 ft.
3
70 ft.
4
60 ft.
5
55 ft.
0
90 ft.
1
60 ft.
2
45 ft.
3
35 ft.
4
25 ft.
0
90 ft.
1
60 ft.
2
45 ft.
3
35 ft.
0
46 ft.
1
37 ft.
2
30 ft.
3
23 ft.
0
56 ft.
1
48 ft.
2
40 ft.
3
32 ft.
0
43 ft.
1
33 ft.
2
24 ft.
Specification Created 7/15
B
2-1/2"
opening
175 ft.
165 ft.
155 ft.
145 ft.
135 ft.
125 ft.
125 ft.
115 ft.
105 ft.
95 ft.
85 ft.
75 ft.
90 ft.
75 ft.
65 ft.
55 ft.
45 ft.
35 ft.
60 ft.
45 ft.
35 ft.
25 ft.
15 ft.
60 ft.
45 ft.
35 ft.
25 ft.
37 ft.
30 ft.
22 ft.
15 ft.
42 ft.
34 ft.
26 ft.
18 ft.
36 ft.
26 ft.
16 ft.