Download Print this page
GE GTX60GBSJ Installation Information
GE GTX60GBSJ Installation Information

GE GTX60GBSJ Installation Information

With he sensor dry

Advertisement

Quick Links

GTX60GBSJ
GE
Series 6.2 cu. ft. capacity Aluminized alloy drum gas dryer with HE Sensor Dry
®
DimEnsiOns anD installatiOn infOrmatiOn (in inchEs)
Exhaust OptiOn: When viewed from the front
of the unit, exhaust 3-way via rear, left and bottom.
Dryer is shipped exhausted to the rear. Alternate
exhausting knockouts are supplied.
Gas: An individual, properly-grounded branch
circuit, with a three-prong grounding-type receptacle,
protected by a 15 or 20 amp circuit breaker or a time-
delay fuse is required.
Gas DryEr ElEctric ratinG: 120V, 60Hz, 6A
Gas (Btu/hr): 22,000. Factory-equipped for
natural gas. Tested for LP gas. LP gas supply requires
a conversion kit. Check installation instructions for
correct kit and have a qualified gas technician install a
conversion kit. See dryer ducting information for proper
installation.
nOtE: Dryer wall outlet must be located within 36" of
service cord entry and accessible when dryer is mounted
in position.
installatiOn infOrmatiOn: For complete
information, see installation instructions packed with
your dryer.
spEcial installatiOn rEquirEmEnts
alcOvE Or clOsEt installatiOn:
- If your dryer is approved for installation in an alcove or closet, it will be stated on a
label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces
are: 0" either side; 3" front and rear
- Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52".
- Closet doors must be louvered or otherwise ventilated and must contain a
minimum of 60 sq. in. of open area equally distributed. If this closet contains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a
gas dryer.
BathrOOm Or BEDrOOm installatiOn:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local
codes, with the National Electric Code and National Fuel Gas Code, ANSI
Z223 for gas dryers.
minimum clEarancEs OthEr than alcOvE Or clOsEt
installatiOn:
- Minimum clearances to combustible surfaces are: 0" both sides; 3" rear
DryEr ExhaustinG infOrmatiOn :
- Use metal duct only, vertical and horizontal ducting.
For answers to your Monogram,
GE Profile
®
or GE
appliance questions, visit our website
®
at geappliances.com or call GE Answer Center
service, 800.626.2000.
®
Specification Created 7/15

Advertisement

loading

Summary of Contents for GE GTX60GBSJ

  • Page 1 DryEr ExhaustinG infOrmatiOn : - Use metal duct only, vertical and horizontal ducting. For answers to your Monogram, GE Profile ® ™ or GE appliance questions, visit our website ® at geappliances.com or call GE Answer Center ® service, 800.626.2000. Specification Created 7/15...
  • Page 2 1 3/4" 5" 4" 3 1/4" Side View Rear View For answers to your Monogram, GE Profile ® ™ or GE appliance questions, visit our website ® at geappliances.com or call GE Answer Center ® service, 800.626.2000. Specification Created 7/15...
  • Page 3: Exhaust Length Calculation

    33 ft. 26 ft. For answers to your Monogram, GE Profile ® ™ Laundry Center GUD24 24 ft. 16 ft. or GE appliance questions, visit our website ® at geappliances.com or call GE Answer Center ® service, 800.626.2000. Specification Created 7/15...
  • Page 4: Features And Benefits

    Model GTX60GBSJWS – White with silver backsplash GTX60EBSJWS_GTX60GBSJWS For answers to your Monogram, GE Profile ® ™ or GE appliance questions, visit our website ® at geappliances.com or call GE Answer Center ® service, 800.626.2000. Specification Created 7/15...

This manual is also suitable for:

Gtd65gbsj