In Command View XP Advanced Edition Software, LUN mapping includes:
Configuring ports
Creating storage groups
Mapping volumes and WWN/host access permissions to the storage groups
For details see the HP StorageWorks XP LUN Manager User's Guide or the HP StorageWorks
Command View XP Advanced Edition Software Device Manager Web Client User's Guide. Note the
LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device
configuration.

Verifying HBA installation

After configuring the ports on the disk array, verify that the HBAs are installed properly.
Use the ioscan –fcommand, and verify that the rows shown in the example are displayed. If these
rows are not displayed, check the host adapter installation (hardware and driver installation) or the
host configuration.
Example
# ioscan –f
Class
I H/W Path
...
fc
0 8/12
lan
1 8/12.5
fcp
0 8/12.8
ext bus
2 8/12.8.0.255.0

Verifying device recognition

Verify that the HP-UX system recognizes the new devices on the disk array.
If the SCSI paths were defined after the system is powered on, you must halt and restart the system
to allow the system to recognize the new devices.
Driver
S/W State H/W Type
fcT1
CLAIMED
fcT1_cntl CLAIMED
fcp
CLAIMED
fcpdev
CLAIMED
XP Disk Array Configuration Guide for HP-UX
Description
INTERFACE HP Fibre ...
INTERFACE HP Fibre ...
INTERFACE FCP Proto...
INTERFACE FCP Devic...