Installation & Servicing Instructions
Greenstar System Filter
For sealed & open vent central heating systems with 22mm central heating pipes
UK/IE

Advertisement

Table of Contents
loading

Summary of Contents for Hyundai CB-L1936LCD/DVD

  • Page 1 Installation & Servicing Instructions Greenstar System Filter For sealed & open vent central heating systems with 22mm central heating pipes UK/IE...
  • Page 2: Table Of Contents

    Contents Contents Symbols and safety precautions Explanation of symbols Symbols and safety precautions ....2 Warning symbol Explanation of symbols ....2 Safety precautions .
  • Page 3: Safety Precautions

    Symbols and safety precautions Safety precautions Fitting and modification The unit must not be fitted in any way other than described in the Installation Instructions and any misuse or unauthorised modifications to the unit or associated components and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions.
  • Page 4: Standard Package

    Standard package Standard package Installation location within system pipework 6720803839-02.2Wo Fig. 2 Open vented system Fig. 1 Standard package [1] Greenstar system filter [2] Copper tails and fittings (22mm) [3] Tool for body [4] Tool for cap General information The Greenstar System Filter is suitable for 22mm pipe central heating systems and can be fitted anywhere on the main heating circuit, except between the boiler and the feed and expansion on an open vent system.
  • Page 5: 2.1.1 Pipework Orientation

    Standard package 2.1.1 Pipework orientation 2.1.2 Dimensions There are various orientations for the pipework to allow for 45mm multiple installation situations. See figure 4 for our advised installation position when installing under a boiler. 35mm 145mm Ø 139mm Fig. 5 Dimensions Fig.
  • Page 6: Installation

    Installation Installation ▶ Drain the central heating or isolate the feed and expansion ▶ Tighten the compression fittings firmly, but do not over tank and release the system pressure. tighten. ▶ Measure, mark and cut out a 70mm section of pipe. ▶...
  • Page 7: Servicing

    Servicing Servicing ▶ Remove the base [1] from the system filter, ensuring that NOTICE: Before commencing any servicing any water or debris is caught within the container. work, turn off the electrical supply to the ▶ Slide the magnetic cap sheath off the base [2]. boiler.
  • Page 8: Chemical Dosing

    Chemical dosing ▶ Using a suitable spanner open the isolation valves (If the ▶ Attach the chemical adaptor and feed in the chemical. filter is used on a sealed system, recharge the system to ▶ Wait five seconds before removing the adaptor. correct working pressure).
  • Page 9: Service Record

    Service record Service record It is recommended that your system filter is serviced regularly and that the appropriate Service Interval Record is completed. Service Provider Before completing the appropriate Service Record Below, please ensure you have carried out the service as described in the servicing section of the manual.
  • Page 10 Notes System Filter– 6 720 803 839 (2014/03)
  • Page 11 Notes System Filter– 6 720 803 839 (2014/03)
  • Page 12 WORCESTER, BOSCH GROUP: TECHNICAL SUPPORT: 0330 123 3366 APPOINTMENTS: 0330 123 9339 SPARES: 0330 123 9779 LITERATURE: 0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0330 123 9559 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd.