Range Of Usage & Limitation - Mitsubishi SRC92ZL-S Technical Manual & Parts List

Inverter wall mounted type residential air-conditioner
Table of Contents

Advertisement

6. RANGE OF USAGE & LIMITATION
6. RANGE OF USAGE & LIMITATIONS
Item
Indoor return air temperature
(Upper, lower limits)
Outdoor air temperature
(Upper, lower limits)
Refrigerant line (one way) length
Vertical height difference between
outdoor unit and indoor unit
Power source voltage
Voltage at starting
Frequency of ON-OFF cycle
ON and OFF interval
Selection chart
Correct the cooling and heating capacity in accordance with the conditions as follows. The net cooling and heating capacity can be
Net capacity = Capacity shown on specification
obtained in the following way.
(1) Coefficient of cooling and heating capacity in relation to temperatures
Net capacity = Capacity shown on specification × Correction factors as follows.
(1) Coefficient of cooling and heating capacity in relation to temperatures
Model
1.3
1.3
1.2
1.2
1.1
1.1
1.0
1.0
0.9
0.9
0.8
0.8
0.7
0.7
0.6
0.6
46
46
40
40
35
35
30
30
25
25
20
20
0
0
-5
-5
-10
-10
-15
-15
14
14
Indoor air W.B. temperature °C W.B
Indoor air W.B. temperature °C W.B
27
25
30
20
25
15
20
10
15
-15
-10
-5
-10
-5
Outdoor air W.B. temperature °C W.B.
Outdoor air W.B. temperature °C W.B.
SRK25ZJP-S1, 35ZJP-S1
SRK92ZL-S
Cooling operation : Approximately 18 to 32℃ D.B.
Heating operation : Approximately 15 to 30℃ D.B.
(Refer to the selection chart)
Cooling operation : Approximately -15 to 46℃ D.B.
Heating operation : Approximately -15 to 24℃ D.B.
(Refer to the selection chart)
Max. 30m
Max. 20m (Outdoor unit is higher)
Max. 20m (Outdoor unit is lower)
Rating ±10%
Min. 85% of rating
Max. 6 times/h
(Inching prevention 6 minutes)
Min. 3 minutes
Correction factors as follows.
Cooling
Cooling
Heating
Heating
Applicable range
Applicable range
Depends on installed situation
Depends on installed situation
16
16
18
18
20
20
.
.
ISO-T1 Standard Condition
ISO-T1 Standard Condition
0
5
10
0
5
10
ISO-T1 Standard Condition
ISO-T1 Standard Condition

-
-
'12 • SRK-T-130
SRK50ZJP-S1
7
26
26
24
24
22
22
15
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk92zl-s

Table of Contents