ADT 3000EN Programming Manual page 6

Safewatch pro
Hide thumbs Also See for 3000EN:
Table of Contents

Advertisement

, 60
TROUBLE REPORT CODE
, 61
BYPASS REPORT CODE
, 62
AC LOSS REPORT CODE
, 63
LOW BAT REPORT CODE
, 64
TEST REPORT CODE
Periodic Test Report Scheduling Commands:
installer code + [#] + [0] + 0 = report every 24 hrs
installer code + [#] + [0] + 1 = report once per week
installer code + [#] + [0] + 2 = report every 28 days
, 65
OPEN REPORT CODE
, 66
ARM AWAY/STAY RPT CODE
UL: † Required for UL commercial burglar alarm installations. †† Required for UL commercial burglar alarm and residential fire alarm
installations. ††† Required for residential fire alarm installations. †††† Must be enabled if wireless devices are used.
, 67
RF XMTR LOW BAT REPORT CODE
, 68
CANCEL REPORT CODE
, 69
RECENT CLOSING REPORT CODE
Also see field *59.
, 70
ALARM RESTORE RPT CODE
, 71
TROUBLE RESTORE RPT CODE
, 72
BYPASS RESTORE RPT CODE
, 73
AC RESTORE RPT CODE
, 74
LOW BAT RESTORE RPT CODE
, 75
RF XMTR LO BAT RST RPT CODE
, 76
TEST RESTORE RPT CODE
OUTPUT AND SYSTEM SETUP ( , , , , 77 – , , , , 93)
, 77 DAYLIGHT SAVINGS TIME
START\END MONTH
, 78 DAYLIGHT SAVINGS TIME
START\END WEEKEND
MENU MODES
∗ 79, *80, *81, *82
, 84
AUTO STAY ARM
, 85
CROSS ZONE TIMER
This option not for use in UL installations.
NOTE : Cross zones take effect only after exit delay
expires.
, 86
CANCEL VERIFY DISPLAY
, 89
EVENT LOG FULL REPORT CODE
, 90
EVENT LOG ENABLES
NOTE: System messages are logged when
any non-zero selection is made.
|
[10]
|
[00]
|
[00]
|
[10]
|
[10]
[0,0,0]
Part. 1 Part. 2 Common
Part. 1)
Away Stay (
Away Stay (
NOTE: "OPEN" reports are not sent if the associated closing report is not enabled.
|
[10]
Any non-zero entry in first digit enables report. ††††
|
[10]
SIA NOTE: Report enabled.
|
[11]
SIA NOTE: Always enabled. Sends both recent closing and zone
alarm reports if fault occurs within 2 min. after exit time expires.
[1]
Any non-zero entry enables report. ††
|
[10]
Any non-zero entry in first digit enables report.†††
|
[00]
Any non-zero entry in first digit enables report.†
|
[00]
Any non-zero entry in first digit enables report.††
|
[10]
Any non-zero entry in first digit enables report.††
|
[10]
Any non-zero entry in first digit enables report. ††††
|
[10]
Any non-zero entry in first digit enables report.††
|
[3][11]
|
[2][1]
These are Menu Mode commands, not data fields, for Output Device Mapping, Output
Programming, Zone List Programming, and Alpha Programming respectively. See
page 2 and their respective sections in the Installation and Setup Guide for procedures.
[3]
[0]
(assign cross zones on zone
list 4, with *81 Menu mode)
[1]
|
[00]
[15]
Example: To select
"Alarm/Alarm Restore", and
"Open/Close", enter 9 (1 + 8);
To select all, enter #15.
– 6 –
Any non-zero entry in first digit enables report. ††
Any non-zero entry in first digit enables report. †
Any non-zero entry in first digit enables report. ††
Any non-zero entry in first digit enables report. ††
Any non-zero entry in first digit enables report. ††
Use Scheduling mode (event 11) or the key commands
listed
below to set periodic test reports. Each command sets
schedule 32 to the stated repeat option; first test report
sent 12 hours after command.
NOTE: Make sure the Real-Time Clock is set to the proper
time before entering the test report schedule command to
ensure that test reports are sent when expected.
Any non-zero entry enables report for partition. †
[0,0,0,0,0,0] A ny non-zero entry
Part. 2)
Common)
Away Stay (
0 = disabled
1-12 = month (1 = January, 2 = February, etc)
#+10 = October; #+11 = November; #+12 = December
0 = disabled, 1 = first, 2 = second, 3 = third
4 = fourth, 5 = last, 6 = next to last, 7 = third to last
0 = no, 1 = partition 1 only
2 = partition 2 only, 3 = both partitions
0 = 15 seconds
6 = 2-1/2 min
1 = 30 seconds
7 = 3 min
2 = 45 seconds
8 = 4 min
3 = 60 seconds
9 = 5 min
4 = 90 seconds
#+10 = 6 min
5 = 2 minutes
#+11 = 7 min
0 = no, 1 = yes
Enter any digit (other than "0") in the first box, to enable
report (entries in the second box are ignored)
0 = None
1 = Alarm/Alarm Restore
2 = Trouble/Trouble Restore
4 = Bypass/Bypass Restore
8 = Open/Close
enables report
#+12 = 8 min
#+13 = 10 min
#+14 = 12 min
#+15 = 15 min