22 CTM Commands
Parameter 0: condition
31
30
29
28
Bits
2:0
31:3
Set Condition Location Command
The set_cond_loc command takes a single parameter that controls the conditional test return value for requests
either from the PE requests or the DPP. If the location is set to the DPP, the CO always returns true to the PE and
performs the conditional test for any DPP request. Conversely, if the location is set to the PE, the CO always returns
true to the DPP and performs the conditional test for any PE request. The location is maintained until the next
set_cond_loc
Parameter 0: loc
31
30
29
28
Bits
0
31:1
ATI CTM Guide v. 1.01
27
26
25
24
23
22
21
Field Name
condition
Reserved
command is received.
27
26
25
24
23
22
21
Field Name
loc
Reserved
20
19
18
17
16
15
14
13
Description
Test Condition:
• 0 - Never (always false)
• 1 - Less (true if client value is less than buffer value)
• 2 - Less or Equal (true if client value is less or equal to buffer value)
• 3 - Equal (true if client value equals buffer value)
• 4 - Greater or Equal (true if client value is greater or equal to buffer value)
• 5 - Greater (true if client value is greater than buffer value)
• 6 - Not Equal (true if client value is not equal to buffer value)
• 7 - Always (always true)
Reserved
20
19
18
17
16
15
14
13
Description
Sets the location of the conditional test:
• 0 - DPP
• 1 -- PE
Reserved
12
11
10
9
8
7
6
5
12
11
10
9
8
7
6
5
© 2006 Advanced Micro Devices, Inc.