Sanyo VCC-9250P Instruction Manual page 4

Colour compact pre-set camera
Table of Contents

Advertisement

PARTS NAMES
Power unit
1
24V AC output terminals (AC24V OUT)
Connect the camera power input terminals (AC24V) to the
power unit output terminals.
2
24V AC input terminals (AC24V IN)
Connect the AC 24V power input to the power unit. When
making the connections, make sure to turn off the power at
the source.
3
Power switch (POWER)
To turn the power on or off. Will also control the power to
the camera.
4
Transmission speed setting switch (RS-485 BAUD RATE)
The default setting is all "ON".
Transmission speed setting (SW1, 2)
The default setting is 19200 bps. If necessary, change
the setting according to the maximum transmission
speed supported by the peripheral devices.
(2400 bps)
(4800 bps)
Alarm duration setting (SW3)
The default setting is 5 sec. If necessary, change the
setting according to the type of alarm signal input.
(5 sec.)
Alarm list display setting (SW4)
The alarm list can be displayed on the menu screen of
the system controller.
The default setting is "ON".
1
AC24V OUT
RS-485
RS-485
BAUD RATE
ADDRESS
1
4
1
7
OFF
OFF
8
TERMINATE
4
5
(9600 bps)
(19200 bps)
(30 sec.)
2
AC24V IN
RS-485 DATA
ALARM IN
A B A B G
1 2 3 4 5 6 7 8 G
6
7
5
Address/Terminate setting switch (RS-485 ADDRESS/
TERMINATE)
Address setting (SW1 to SW7)
Set the power unit address. See the table on page 12, for
details.
Termination setting (SW8)
The power unit termination must be set. The default
setting is all OFF (up).
6
RS-485 control terminal (RS-485 DATA)
Make the connections between the RS-485 terminals of the
camera, power unit, system controller, etc. using
twisted-pair cable or modular cable (sold separately). Signal
A must be connected to A, and signal B to B.
7
Alarm input terminals (ALARM IN)
Connect alarm input sources such as a door bell, an
interphone, etc. to the ALARM IN terminals. Refer to
"Connections to the ALARM IN terminal" on page 4, for
more information on connections.
8
Power indicator viewing hole
The indicator inside the hole illuminates when the power is
turned on.
9
Fuse socket
3
3
POWER
8 9
ADDRESS SET
TERMINATER
ON/OFF

Advertisement

Table of Contents
loading