WIRING REQUIREMENTS

The cooker MUST be installed in compliance with:
wiring connections in AS/NZS 3000 Wiring Rules.
local regulations, municipal building codes and
other statutory regulations.
For New Zealand Only:
The cooking range must be connected to the supply by
a supply cord fitted with the appropriately rated plug
that is compatible with the socket-outlet fitted to the
final sub-circuit in the fixed wiring that is intended to
supply this cooking range.
Supply cord size required:
WFE914SB/WVE914SB/WVE916SB - 1.5mm
WFEP915SB/WVEP916SB - 4.0mm
WFE946SB - 6.0mm
The Data plate gives information about rating and is
located behind the bottom of the oven door.
A functional switch MUST be provided near the
appliance in an accessible position (AS/NZS 3000
- Clause 4.7.1).
Wiring MUST be protected against mechanical
failure (AS/NZS 3000 - Clause 3.9).
The cooker requires a means of all pole
disconnection incorporated into the fixed wiring.
This MUST have a disconnection gap of 3mm.
The cooker MUST be properly earthed.
This range must be connected with cable of 75°C
rating minimum.
This product has passed the insulation resistance
test after manufacture. If the resistance reading
is low at installation, it is probably caused by
moisture from the atmosphere being absorbed by
the elements after the range has been produced.
(pass at 0.01 M AS/NZS 3000 Wiring Rules Clause
8.3.6.2).
Note: When connections are made to a multi-phase
230/240V supply, the bridge piece MUST be removed
from between the active connections.
Rated power input
MODEL
TOTAL KW
WFE946
13.1
TIPS & INFORMATION
IMPORTANT
Before you cook in your new oven it is important that
the protective oils used in the manufacture of the
product be removed.
Make sure that the room is well ventilated (to allow
smoke to escape).
Run the grill on high for 30 minutes without grill dish.
Then run the oven on 180°C for 1 hour.
42
WIRING REQUIREMENTS
2
2
2
A1 KW
A2 KW
3.6
9.5
Connecting to services and commissioning
This appliance must be installed by an authorised
person, according to all codes and regulations of:
Electrical supply authorities.
Building regulations.
Local government and council authorities.
AS/NZS5601.1(particular attention to 6.10.1 and
figure 6.3, and clause 6.10.1.11).
AS/NZS 3000 (particular attention to clause 4.3.11
and clause 3.9).
Hard wiring detail
1.
Remove terminal cover plate from rear panel of
appliance.
2.
Fit wires through hole in cover plate and make
connections to terminals.
3.
Engage wires into plastic clip. Secure plastic clip
with two long silver screws (supplied in separate
bag).
4.
Replace cover plate onto rear panel.
Electrical connection location - built-in models
Entry point of electrical cable
Plastic clips
Plastic clip
Securing points
113
99