Kenwood DPX701 Service Manual page 17

Hide thumbs Also See for DPX701:
Table of Contents

Advertisement

• By pressing [AUD] or [FM] key briefly, switch the item to be
adjusted in the following order. (only in forward rotation)
The initial item will be Fader, which is followed by : Balance
→ Bass Level → Middle Level → Treble Level → HPF Front
→ HPF Rear → LPF Sub Woofer (After this, it will be arbi-
trary)
• With the remote controller, continuous forwarding is pro-
hibited.
• Using the VOL knob and [
adjusted in 3 steps : R15 ↔ 0 ↔ F15 (The initial value is 0)
• Using the VOL knob and [
be adjusted in 3 steps : L15 ↔ 0 ↔ R15 (The initial value is 0)
• Using the VOL knob and [
/ Treble Level can be adjusted in 3 steps : –8 ↔ 0 ↔ +8
(The initial value is 0)
• Using the VOL knob and [
Rear can be adjusted in 2 steps : Through ↔ 220Hz (The
initial value is Through)
• Using the VOL knob and [
Woofer can be adjusted in 2 steps : 50Hz ↔ Through (The
initial value is Through)
• Using the VOL knob and [
Phase can be adjusted in 2 steps : Reverse ↔ Normal (The
initial value is Normal)
• Using the VOL knob and [
set can be adjusted in 2 steps : –8 ↔ 0 (The initial value is
0)
• Using the VOL knob and [
ON/OFF can be adjusted in 2 steps : OFF ↔ ON (The
initial value is OFF)
• Using the VOL knob and [
can be adjusted in 2 steps : OFF ↔ ON (The initial value is
OFF)
• Bass f / Bass Q / Bass EXT / Middle f / Middle Q / Treble f
do no appear in audio adjustments.
MENU items
• Press [Q] key briefly to enter the MENU.
• The [DNPP/SBF] and [DIRECT] keys on the remote con-
troller can also be used to enter the MENU.
• With the remote controller, continuous forwarding is pro-
hibited.
• When a CD/USB is used as a source, the default item will
be the F/W Version.
2-ZONE (Dual Zone) items
• When using sources other than the STANDBY source, us-
ing a short-press on [AUTO] or [TI] key, 2-ZONE ON/OFF
is achieved.
TEST MODE
] / [
] key, the Fader can be
] / [
] key, the Balance can
] / [
] key, the Bass / Middle
] / [
] key, the HPF Front /
] / [
] key, the LPF Sub
] / [
] key, the Sub Woofer
] / [
] key, the Volume Off-
] / [
] key, the Loudness
] / [
] key, 2-Zone ON/OFF
DPX701/701U/701UY
DPX-MP7090U
Backup current measurement
When reset in Acc OFF (Back Up ON) condition, MUTE termi-
nal goes off after 2 seconds, instead of 15 seconds. (During
this time, the CD mechanism does not function.)
OPEL communication items (OPEL communica-
tion specification supporting model)
During the test mode, OPEL communication line outputs the
following (At every 500msec, the output condition of the com-
munication line will be switched.)
CE
DATA
CLK
500msec
500msec
500msec
G sensor display items (G-Analyzer supporting
model)
When source is STANDBY, by short-pressing [ATT] key, the
display is switched to analogy meter display, in which vertical
G and horizontal G are displayed.
Special display when all lights are on
When all lights are on with the STANDBY source, the follow-
ing displays are made when the keys shown below are pressed.
[1] key Version display
(Display) C0528WK__SYS1. 23
(Display) STYPE : x__PAN1.11
(Display) PTYPE : x__MEM3.21
∗ STYPE indicates system µ-com destination, and PTYPE
indicates panel µ-com destination, and show real-time
condition of the destination terminal ("x" is displayed in
hexadecimals.)
[2] key Serial number display (8 digits)
(Display) SNo_xxxxxxxx
[3] key Key pressed briefly : Power ON time is displayed.
(Display) PonTim_0Hxx_ (00~50 is displayed for "xx".
xxxxx (00001~10922 is displayed for
During Power On time display, by pressing for at least 2
seconds, the Power ON time is cleared.
When less than 1 hour, displayed
by increments of 10 minutes.)
"xxxxx".) MAX 10922 (times)
17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpx701uDpx701uyDpx-mp7090u

Table of Contents