AC 220-240V
Downloaded From WashingMachine-Manual.com Manuals
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
When disconnecting the connector (1) on the
(1)
PWB assembly (Main) is the resistance of the
Natural connectors [ (Blue White),
between 2.5kΩ to 180kΩ(105°C~0°C)?
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
(White)]
1
6
22
Replace the thermistor
Push the thermistor
tightly to the rubber.