4.3.6. Reference (White Balance Adj. coordinate
and temperature)
A
Luminance : 216 Gray
Standard color coordinate and temperature using CS-1000
A
(over 66cm(26 inch))
Mode
Color Coordination
x
COOL
0.269
MEDIUM
0.285
WARM
0.313
Standard color coordinate and temperature using CA-210
A
(CH 14)
Mode
Color Coordination
x
COOL
0.269 ± 0.002
MEDIUM
0.285 ± 0.002
WARM
0.313 ± 0.002
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
1) Edge / IOP LED Models
Cool
Aging time
GP2
x
y
(Min)
269
273
1
0-2
280
291
2
3-5
278
288
3
6-9
276
285
4
10-19
274
282
5
20-35
273
279
6
36-49
270
276
7
50-79
269
273
8
Over 80
269
273
4.3.7 Local Dimming Inspection
Edge LED models with local dimming
1) Press 'TILT" key of the Adj. R/C and check moving patterns.
The black bar patterns moves from left to right.If local dimming function
does not work, a whole screen shows full white.
4.3.8 IOP LED models with local dimming
Press 'TILT" key of the Adj. R/C and check moving patterns.
The black cross-bar patterns moves from top-left to Bottom-right.
If local dimming function does not work, a whole screen shows full white.
4.4. EYE-Q function check
Step 1) Turn on TV
Step 2) Press EYE key of Adj. R/C
Step 3) Cover the Eye Q II sensor on the front of the using
your hand and wait for 6 seconds
Copyright © 2010 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Temp
∆UV
y
0.273
13000 K
0.0000
0.293
9300 K
0.0000
0.329
6500 K
0.0000
Temp
y
0.273 ± 0.002 13000 K
0.0000
0.293 ± 0.002
9300 K
0.0000
0.329 ± 0.002
6500 K
0.0000
Medium
Warm
x
y
x
y
285
293
313
329
296
311
319
340
294
308
317
338
292
305
315
335
290
302
313
332
289
299
312
329
287
296
310
326
286
293
308
323
285
293
308
323
Step 4) Confirm that R/G/B value is lower than 10 of the "Raw
Data (Sensor data, Back light)". If after 6 seconds,
R/G/B value is not lower than 10, replace Eye Q II
sensor.
Step 5) Remove your hand from the Eye Q II sensor and wait
for 6 seconds.
Step 6) Confirm that "ok" pop up. If change is not seen,
replace Eye Q II sensor.
4.5. Option selection per country
(1) Overview
- Option selection is only done for models in Non-USA
North America due to rating.
- Applied model: LC03E Chassis applied None USA model
(CHINA, HONGKONG)
∆UV
(2) Method
1) Press ADJ key on the Adj. R/C, then select Country
Group Menu
2) Depending on destination, select KR or US, then on the
lower Country option, select US, CA, MX. Selection is
done using +, - KEY.
4.8. Tool Option selection
- Method : Press Adj. key on the Adj. R/C, then select Tool
option.
MODEL
47LE85**
4.9. Ship-out mode check(In-stop)
After final inspection, press IN-STOP key of the Adj. R/C and
check that the unit goes to Stand-by mode.
After final inspection, Always turn on the Mechanical S/W.
5. GND and Internal Pressure check
5.1. Method
1) GND & Internal Pressure auto-check preparation
- Check that Power Cord is fully inserted to the SET.
(If loose, re-insert)
2) Perform GND & Internal Pressure auto-check
- Unit fully inserted Power cord, Antenna cable and A/V
arrive to the auto-check process.
- Connect D-terminal to AV JACK TESTER
- Auto CONTROLLER(GWS103-4) ON
- Perform GND TEST
- If NG, Buzzer will sound to inform the operator.
- If OK, changeover to I/P check automatically.
(Remove CORD, A/V form AV JACK BOX)
- Perform I/P test
- If NG, Buzzer will sound to inform the operator.
- If OK, Good lamp will lit up and the stopper will allow the
pallet to move on to next process.
5.2. Checkpoint
• TEST voltage
- GND: 1.5 KV / min at 100 mA
- SIGNAL: 3 KV / min at 100 mA
• TEST time: 1 second
• TEST POINT
- GND TEST = POWER CORD GND & SIGNAL CABLE
METAL GND
- Internal Pressure TEST = POWER CORD GND & LIVE &
NEUTRAL
• LEAKAGE CURRENT: At 0.5 mArms
- 12 -