Servicing The Fuses - Toro 74386 Operator's Manual

Hide thumbs Also See for 74386:
Table of Contents

Advertisement

1. Positive battery post
2. Negative battery post
Note: Do not run the machine with the battery
disconnected, electrical damage may occur.
Installing the Battery
1. Position the battery in the tray (Figure 46).
2. Install the positive (red) battery cable to the positive (+)
battery terminal using the fasteners removed previously.
3. Install the negative battery cable to the negative (-)
battery terminal using the fasteners removed previously.
4. Slide the red terminal boot onto the positive (red)
battery post.
5. Secure the battery with the hold-down (Figure 46).
6. Lower the seat.

Servicing the Fuses

The electrical system is protected by fuses. It requires
no maintenance; however, if a fuse blows, check the
component/circuit for a malfunction or short.
Fuse:
Main F1-30 amp, blade-type
Charge Circuit F2-25 amp, blade-type
1. Remove the screws securing the control panel to the
machine. Retain all fasteners
2. Lift the control pane up to access the main wiring
harness and fuse block (Figure 48).
3. To replace a fuse, pull out on the fuse to remove it
(Figure 48).
Figure 47
3. Red (+) charger lead
4. Black (-) charger lead
2
1. Main-30 amp
4. Return the control panel to its original position. Use
the screws removed previously to secure the panel to
the machine.
38
1
G014921
Figure 48
2. Charge circuit-25 amp