Toro 41178 Multi-Pro 1200 Operator's Manual page 19

Turf sprayer
Table of Contents

Advertisement

speed. This is necessary to run the chemical agitation
while stationary or operating attachments such as the
hand sprayer (Figure 14).
Important: The range selector must be in the
neutral position for the switch to work.
Fuel Gauge
The fuel gauge is located on top of the fuel tank, on
the right side of the machine and shows the amount of
fuel in the tank.
Master Spray Lever
The master spray lever allows you to start or stop the
spray operation. Rotate the lever forward to enable
the spray system and rearward to disable it (Figure 15).
When the master spray lever is in the Off position, the
Spray Pro screen reads "Hold."
Figure 15
1. Master spray lever
2. Boom levers
Boom Levers
The boom levers are located at the rear of the control
panel to the right of the seat (Figure 15). Push each lever
down to turn the corresponding boom section on and
up to turn them off. These levers will only affect the
spray system when the master spray lever is on.
Application Rate Knob
The application rate knob is located on the control
panel to the right of the seat (Figure 15). Rotate the
knob clockwise to increase the spray system pressure or
counterclockwise to decrease pressure.
3. Application rate knob
4. Pump switch
Pump Switch
The pump switch is located on the control panel to the
right of the seat (Figure 16). Toggle this switch forward
to run the pump or rearward to stop the pump.
Important: Only engage the pump switch when
the engine is at low idle to avoid damaging the
pump drive.
1. Pump switch
2. Boom lift switch, left and
right
Boom Lift
The boom lift switches are used to raise the left and
right boom respectively (Figure 16).
Foam Marker Switch Locations
(Optional)
If you install the electric boom lift, sonic boom, and
foam marker kit, you will add switches to the control
panel for controlling their operation. The sprayer comes
with plastic plugs in these locations.
Sonic Boom (Optional)
The Sonic Boom switch is a rocker switch used to
operate the Sonic Boom. Toggle switch forward for
automatic, rearward for manual and center for Off.
Application Rate Control Valve
This valve controls the amount of fluid that is routed
to the booms by directing fluid flow to the booms or
the bypass hose to the tank (Figure 17). To control this
valve, rotate the application rate knob on top of the
valve to obtain the desired pressure.
19
Figure 16
3. Foam marker switch, left
and right
4. Sonic boom switch

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi-pro 1200

Table of Contents