DO NOT INSTALL THE CONTROLLERS
• NEAR A HEAT SOURCE, SUCH AS A COOK TOP, STOVE OR OVEN. HEAT, STEAM,
SMOKE AND HOT OIL MAY CAUSE DAMAGE
• IN DIRECT SUNLIGHT
• OUTDOORS UNLESS AN ENCLOSURE IS PROVIDED WHICH PROTECTS THE
CONTROLLER AGAINST SUNLIGHT AND DUST INGRESS.
• AGAINST A METAL WALL UNLESS THE WALL IS EARTHED IN ACCORDANCE
WITH AS/NZ3000.
Remote Controller Connection
Remote controls operate at extra low voltage (12 Volts DC) which is supplied from the appliance.
Controllers are supplied with 15 m of electrical cable. The cable wires for connection to the appliance are
fitted with spade terminals.
Extension cables are available from Rinnai. Alternatively, a two core sheathed (double insulated) flex with
minimum cross-sectional area of 0.5 mm² can be used. Maximum cable length is 50 m.
For connection refer to the "CONNECTING REMOTE CONTROL CABLES" section.