Sony TRINITRON KV-32FV27 Service Manual
Sony TRINITRON KV-32FV27 Service Manual

Sony TRINITRON KV-32FV27 Service Manual

Hide thumbs Also See for TRINITRON KV-32FV27:

Advertisement

SERVICE MANUAL

MODEL NAME
KV-32FV27
KV-32FV27
KV-36FS13
KV-36FS13
KV-36FS13H
KV-36FS17
KV-36FS17H
KV-36FV27
KV-36FV27
KV-36FV27H
KV-38FS17
9-965-901-01
REMOTE COMMANDER
DESTINATION
RM-Y182
RM-Y182
RM-Y180
RM-Y180
RM-Y180
HAWAII
RM-Y181
RM-Y181
HAWAII
RM-Y182
RM-Y182
RM-Y182
HAWAII
RM-Y181
KV-36FV27
TRINITRON
AA-2U
CHASSIS NO.
US
SCC-S44KA
CND
SCC-S45GA
US
SCC-S44HA
CND
SCC-S45EA
SCC-S46FA
US
SCC-S44GA
SCC-S46EA
US
SCC-S44JA
CND
SCC-S45FA
SCC-S46GA
E
SCC-S50EA
RM-Y182
®
COLOR TELEVISION
Self Diagnosis
Supported model
CHASSIS

Advertisement

Table of Contents
loading

Summary of Contents for Sony TRINITRON KV-32FV27

  • Page 1: Service Manual

    Self Diagnosis Supported model AA-2U SERVICE MANUAL CHASSIS MODEL NAME REMOTE COMMANDER DESTINATION CHASSIS NO. KV-32FV27 RM-Y182 SCC-S44KA KV-32FV27 RM-Y182 SCC-S45GA KV-36FS13 RM-Y180 SCC-S44HA KV-36FS13 RM-Y180 SCC-S45EA KV-36FS13H RM-Y180 HAWAII SCC-S46FA KV-36FS17 RM-Y181 SCC-S44GA KV-36FS17H RM-Y181 HAWAII SCC-S46EA KV-36FV27 RM-Y182 SCC-S44JA KV-36FV27 RM-Y182...
  • Page 2: Section 4: Circuit Adjustments

    KV-32FV27 / 36FS13 / 36FS17 / 36FV27/ 38FS17 SECTION 4: CIRCUIT ADJUSTMENTS ELECTRICAL ADJUSTMENTS BY REMOTE COMMANDER Use the Remote Commander (RM-Y180, RM-Y181, RM-Y182) to perform the circuit adjustments in this section. Test Equipment Required: 1. Pattern generator 2. Frequency counter 3. Digital multimeter 4. Audio oscillator 4-2.
  • Page 3 4-4. ADJUSTMENT ITEMS (1 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"/38" Comments Register Name Range Data HPOS H-Position 0-63 0: 2ms delay, 63: 2ms advance HSIZ H-Size 0-63 EW DC bias, 0: -0.5V, 31: 0V, 63: +0.5V VBOW 0-15 0: top/bottom delay 900ns, 7: center, 15: top/bottom advance 900ns...
  • Page 4 ADJUSTMENT ITEMS (2 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"/38" Comments Register Name Range Data YSPF 0=2.5MHZ, 1=3.0MHz Sharpness fo for YUV Input AXNT 0: Japan Axis, 1: US Axis Axis NTSC PREL 0: 1:1, 1: 2:1...
  • Page 5 ADJUSTMENT ITEMS (3 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"/38" Comments Register Name Range Data ST0S Select ST0 Pin Output Signal External Y-ADC clamp pulse Noise Detection Coring 1LSB coring for noise detection circuit VTRH H-sync Non-Standard Detection Hysteresis Low hysteresis (2 clock pulses)
  • Page 6 ADJUSTMENT ITEMS (4 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"38" Comments Register Name Range Data GCUR Controls Curve of Gamma Correction 0: -2.4dB, -1.6dB BLKC Black Conpensation PIC IMP TEST Pin 20 Output: 0=RS, 1=SHR, 2=RTC, 3=TEST3 Test Bit TA1226N...
  • Page 7 ADJUSTMENT ITEMS (5 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"/38" Comments Register Name Range Data PUGA Peak Level U Output 0-255 0: 0.3Vpp, 192: 1.0Vpp, 255: 1.2Vpp 4PUG Peak Level U Output YUV Input 0-255 0: 0.3Vpp, 192: 1.0Vpp, 255: 1.2Vpp PYGA...
  • Page 8: Feature Id Map

    ADJUSTMENT ITEMS (6 OF 6) KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 Description Data Adj/Fix Initial 32" 36"/38" Comments Register Name Range Data RDOF Red Drive offset for WARM 0-63 Red Drive MOVIE=RDRV(RDR4)-RDOF GDOF Green Drive offset for WARM 0-63 Green Drive MOVIE=GDRV(GDR4)-GDOF BDOF...
  • Page 9: A Board Adjustments

    KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 TO PROGRAM PROGRAM PALETTE RESET SUB HUE, SUB COLOR ADJUSTMENT LEVELS (T2HU, T2CO, V2HU, V2CO, 4SHU, 4COL) 1. Switch to Program Palette to edit. Note: T2HU and T2CO are for Tuner inputs. V2HU and V2CO are for all other Video inputs.
  • Page 10 KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 H. SIZE ADJUSTMENT (HSIZ) V ANGLE (VANG), V BOW (VBOW), UPPER PIN (UPIN) AND LOW PIN (LPIN) 1. Input a monoscope signal. ADJUSTMENTS 2. Set to Service Adjustment Mode. 3. Select HSIZ with 1 and 4 . 1.
  • Page 11 KV-32FV27 / 36FS13 / 36FS17 / 36FV27 / 38FS17 ROTATION COIL ADJUSTMENT 1. Input a monoscope signal. 2. Push the Menu button on the Remote. 3. Select the “Set-up” mode. 4. Select “Tilt Correction”. Confi rm that number (0) color changes to red. 5.

Table of Contents