6.0:
Specification
All specifications are for a PSIM supplying a full network of probes.
PSIM-AC
Input
Voltage
Current
Connection
Isolation
Protection
Recommended Line Fuse
DC Output
Output Voltage
Output Current
Output Regulation
Transient Response
Ripple and Noise
Efficiency
Protection
see note 2
Thermal Derating
LDN-PS
85 to 264 Vac @ 47 Hz to 440 Hz.
0.8 A
via IEC320 connector
2500 Vac input/output
Input fuse and filter (not user replaceable)
2A T (slo-blo) 250 V rating
5.1 Vdc Nominal
1.8 A max (i.e. 31 Orbit Modules)
3% (Line / Load)
Max. 4% deviation recovers to 1% within 500 ms
< 1% p-p
65% to 70% typical
The output current shall be derated from 40 °C
to 60 °C by 50%. (ie. Max. output at 60 °C
is 0.9A or 15 Orbit Modules.)
13
PSIM-AC
PSIM-DC
PSIM-5V
M-3340/1206