Flange Back Adjustment (Using The Minipattern Box); Flange Back Adjustment - Sony DSC-P1 Service Manual And Parts List

Hide thumbs Also See for DSC-P1:
Table of Contents

Advertisement

1. Flange Back Adjustment (Using the minipattern box)

The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual forcusing.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Note 1: Dark Siemens star chart.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Menu Setting:
VIDEO OUT of SETUP menu ........... NTSC (NTSC mode)
(This adjustment must be performd in NTSC mode, so don't
set the menu setting to "PAL")
Preparations before adjustments:
1) The minipattern box is installed as shown in the following
figure.
Note 3: The attachment lenses are not used.
Note 4: Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance
between it and the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated
power supply is the specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets
the center of shot image screen with the zoom lens
at TELE end and WIDE end respectively.
6) Check that the data on page: F, address: 14 to 25, 87 to 9B are
initial value (See table below).
Address
Data
14
00
15
00
16
50
17
00
18
11
19
B1
1A
09
1B
0F
1C
00
1D
00
1E
00
1F
00
20
20
Downloaded from
www.Manualslib.com
STILL
Siemens star chart with ND filter
for minipattern box (Note 1)
Check operation on TV monitor
F
"14 to 25, 87 to 9B"
Address
Data
Address
21
20
8F
22
35
90
23
40
91
24
0A
92
25
00
93
87
FF
94
88
00
95
89
00
96
8A
00
97
8B
00
98
8C
00
99
8D
00
9A
8E
00
9B
manuals search engine
Specified voltage: The specified voltage varies according to the
minipatternbox, so adjustment the power supply
output voltage to the specified voltage written
on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Output voltage : Specified voltage ± 0.01 Vdc
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Adjusting method:
Order Page Address Data
1
0
01
2
5
F1
3
D
63
4
5
6
01
Data
6
6
01
00
7
6
02
00
00
8
F
87
00
00
00
Note 5: The adjustment data will be automatically input to page:
00
F, address: 14 to 25 and 87 to 9B.
00
Processing after Completing Adjustment:
00
Order Page Address Data
00
1
6
01
40
2
5
F1
00
3
D
63
40
4
5
0
01
6
5-14
Below 3 cm
Camera
Camera
table
Regulated power supply
Output current : more than 3.5 A
Need not connected
Fig. 5-1-13
Procedure
01
FF
40
Press PAUSE button.
Perform "Data setting during
camera system adjustment".
(Refer to page 5-13)
13
Press PAUSE button.
27
Press PAUSE button. (Note 5)
Check the data changes to
"01".
Check the data.
00: Normal
01 to FF: Defective
Procedure
00
Press PAUSE button.
00
00
Press PAUSE button.
Release the data setting
performed at step 4.
(Refer to page 5-13)
00
Perform "Flange Back
Check".

Advertisement