T
d. Analog output: Read & write voltage:
@
vx<c/r>
(lower case v)
e. Digital Outputs: Write outputs:
a
A
b
B
c
C
d
D
f. Digital Outputs: Read outputs:
O
(upper case o)
g. Digital Inputs: Read inputs & toggling counter:
I
(upper case i)
i
c. Get a single reading of:
weight, A/D or temperature:
Get weight (after Filter2, not rounded to resolution).
Get weight (after Filter2, rounded to resolution).
Gets the analog output voltage (in Volts).
Sets the analog output voltage to
The analog output voltage is measured at pin 12 of CONN6
Card returns a string of the form 'xxxx<c/r>', where
either "1" or "0" representing the status of the 4 output
opto relays OUT4,OUT3,OUT2,OUT1 respectively.
Card returns a string of the form 'xxxx<c/r>', where
either "1" or "0" representing the digital input status of
IN4,IN3,IN2,IN1 respectively.
Gets a 16 bit 'toggling counter'. The 'toggling counter'
increments each time when input #2 is toggled.
30
Get A/D reading after Filter1.
Get A/D reading after Filter2.
with respect to pin 13 which is ground.
Turn on Output1 if Manual
Turn off Output1 if Manual
Turn on Output2 if Manual
Turn off Output2 if Manual
Turn on Output3 if Manual
Turn off Output3 if Manual
Turn on Output4 if Manual
Turn off Output4 if Manual
Get temperature