U24Y101
POWER SUPPLY
M1426/1106
INSTRUCTION
SHEET
Shop online at: omega.com e-mail: info@omega.com
For latest product manuals: omegamanual.info
OMEGA's U24Y101 24 VDC Power
Supply provides low cost DC power
suitable for driving process current
loops, transducers, relays, electro-
mechanical timers, and small motors.
All components are rated to insure high
reliablility, and built-in fusing prevents
damage due to short-circuits or
prolonged overloading.
There are two models:
U24Y101 for 120 Vac power;
U24Y101-220 for 220 Vac power
Either model can be converted to the
other by a solder pad change which is
explained below.
UNPACKING
Remove the packing list and verify that
all equipment has been received. If
there are any questions about the
shipment, please call OMEGA
Customer Service Department at
1-800-622-2378 or (203) 359-1660.
Upon receipt of the shipment, inspect
the container and equipment for any
Printed Circuit Board
Figure 1
signs of damage. Take particular note
of any evidence of rough handling in
transit. Immediately report any damage
to the shipping agent.
NOTE
The carrier will not honor any claims
unless all shipping material is saved for
their examination. After examining and
removing contents, save packing
materials and carton in the event
reshipment is necessary.
INSTALLATION AND
OPERATION
The U24Y101 is provided with a
predrilled base plate for surface
mounting. the power supply should be
mounted in an open area with
unrestricted air movement.
Connections for AC power and DC
output are made via the four position
terminal block. The power can be 120
or 220 VAC and is user selectable by
means of internal jumpers.
CAUTION — MAKE ALL
CONNECTIONS BEFORE
APPLYING POWER!
OMEGA
A
3.00
C
B
MEC 24-1000
MODEL U24Y101
TERMINAL BLOCK
CONNECTIONS
1. AC IN
2. AC IN
3. DC OUTPUT (+)
4. DC OUTPUT (--)
HOW TO CHANGE INPUT
VOLTAGE
1. Remove the screws securing the
bottom covers to gain access to the
printed circuit board.
2. Locate the three solder jumpers
shown in Fig. 1.
a) For 120 VAC operation install
b) For 220 VAC remove solder
3. Relabel unit to reflect power change.
SPECIFICATIONS
Input Power:
Output Voltage:
Output Current:
Load/Line Regulation:
Output Protection:
Input Protection:
Operating Temp:
Storage Temp:
Size:
7.625
FUSE
1
2
3
4
7.00
NOTES:
ALL DIMENSIONS IN INCHES
CASE HEIGHT: 2.520"
(Add for Terminal Block)
Figure 2
solder jumpers at locations A & B
and remove jumper C.
jumper from A & B and install
solder jumper at C.
120 VAC (Std) or
220 VAC (Opt) ± 10%
24 VDC ± 5%
1 Amp (max)
± 2%
Current Limited and
Thermal Limited
0.5 Amp Fuse
–20 to 60 Deg. C
–30 to 70 Deg. C
See Fig. 2
LINEAR POWER SUPPLY
made in USA
.150 Dia.
.150
.150
2.25
4 PLS

Advertisement

loading

Summary of Contents for Omega Engineering U24Y101

  • Page 1 INSTALLATION AND OPERATION The U24Y101 is provided with a predrilled base plate for surface mounting. the power supply should be mounted in an open area with unrestricted air movement.
  • Page 2 OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.