2.1.3

Common Problems

2.1.3.1 Generic Client Drivers
Many Card and Socket Services packages include a generic client driver (or SuperClient)
which configures standard I/O devices. If one of these generic client drivers is installed, it
may configure the IOP-241 causing the client driver to fail installation. In these cases, the user
should do one of the following:
1. Modify the operation of the generic client driver to disable the configuration of
modem/serial port cards. Consult the Card and Socket Services documentation for
availability and details of this feature.
2. Place the IOP-241 client driver entry before the generic client driver entry in the
system CONFIG.SYS file.
2.1.3.2 Available Resources
One function of the Card and Socket Services software is to track which system resources
(memory addresses, I/O addresses, IRQs, etc.) are available for assignment to inserted
PCMCIA cards. Sometimes, however, the software assumes or incorrectly determines that a
particular resource is used when it is actually available. Most Card and Socket Services
generate a resource table in a file (typically in the form of an .INI file) which the user can
modify to adjust the available system resources. Consult the Card and Socket Services
documentation for availability and details of this feature.
2.1.3.3 Multiple Configuration Attempts
Some Card and Socket Services have a setting which aborts the configuration process after a
single configuration failure (such as a request for an unavailable resource). The user should
change this setting to allow for multiple configuration attempts. Consult the Card and Socket
Services documentation for availability and details of this feature.
2.1.3.4 Older Versions of Card and Socket Services
Some versions of Card and Socket Services dated before 1993 do not support general purpose
I/O cards. If after careful installation of the Client Driver the IOP-241 does not configure or
operate properly, an updated version of Card and Socket Services may be required. Card and
Socket Services software is available from Omega.