Range Configuration Code

The AD converter of the OME-A-826PG is 16 bits under all
configuration code. If the analog input range is configured to ±5V range, the
resolution of one bit is equal to 2.44 mV. If the analog input range is configured to
±2.5V range, the resolution will be 1.22 mV. If the analog input signal is about
1 V, use configuration 0/1/2 (for OME-A-826PG), it will get nearly the same result
except resolution. So choose the correct configuration code can achieve
the most high precision measurement.
OME-A-826PG Input Signal Range Configuration Code Table
Bipolar/Unipolar
Bipolar
Bipolar
Bipolar
Bipolar
Date: Aug-15-2000
Input Signal Range
± 10V
± 5V
± 2.5V
± 1.25V
Ver: 2.2
Configuration Code
0
1
2
3
Page 6