Programming Flowchart - Omega DPF500 Series User Manual

Dpf500 series ratemeter/totalizer
Table of Contents

Advertisement

4.2 Programming Flowchart

RUN MODE
If panel
lock OFF
ENTER CODE
CLEAR TOTAL
OTAL
OT
FACTOR
DECIMAL
20poInt
FACTOR
lInear
TYPE
20poInt
selected
FACTOR
SET
YES
20PT
YES
No
SET pnts
M
No
selected
FREQUENCY
for POINT #
(Fr0-Fr19)
If Fr1-FR19 = 0
FACTOR for
POINT #
(FAC0-FAC19)
RATE
RA
RATE
TOTAL
M
If panel
lock ON
0000
ent Code
If code
E
incorrect
If code
correct
E
CLR ToT
M
FDEC
E
12345678
M
FAC
E
20poInt
M
lInear
selected
FAC
E
100
M
E
YES
selected
Fr#
E
#####
M
FaC#
E
#####
M
# = 19
Continue On
Next Page
Press the M key to enter the programming menu.
If the panel lock is on, you must enter the 4 digit lock code to gain access
to the menu.
Press the
key to increment each individual digit of the code.
key to increment each individual digit of the code.
Press the
key to advance to the next digit.
Press the E key to enter the displayed code.
If the code is correct, display advances to "clr tot", if not, display returns
to run mode
Press the E key to clear the totalizer and return to the programming menu.
Press the M key to skip and go to next menu item.
Press the
key to step the factor decimal to the desired location.
Press the E key to enter the displayed decimal location.
Press the M key to skip and keep the existing location
NOTE:
For best performance and resolution choose as many decimal places as
possible in the K-Factor.Example: Enter a K-Factor of 1 as 1.000.
key to choose factor type (20point or linear).
Press the
Press the E key to enter the displayed factor type.
Press the M key to skip and keep the existing factor type.
The FAC prompt will only appear if linear is selected or if the unit was ordered
without the 20 point linearization option.
Press the
key to increment each individual digit of the factor.
key to increment each individual digit of the factor.
Press the
key to advance to the next digit.
Press the E key to enter the displayed factor.
Press the M key to skip and keep the existing factor.
The SET pnts prompt will only appear if 20point is selected. This allows users
to bypass the 20 point set up and keep the existing values.
to bypass the 20 point set up and keep the existing values.
Press the
key to choose YES or NO.
Press the E key to enter the displayedselection.
Press the M key to skip (same as selecting NO).
Press the
key to increment each individual digit of the frequency for point
#.
Press the
key to advance to the next digit.
Press the E key to enter the displayed frequency.
Press the M key to skip and keep the existing frequency.
If 0 is entered, the display will advance to the next prompt (tdec).
NOTE: Frequency/factor point pairs must be entered in ascending order of fre-
quency
Press the
key to increment each individual digit of the factor for point #.
key to increment each individual digit of the factor for point #.
Press the
key to advance to the next digit.
Press the E key to enter the displayed factor.
Press the M key to skip and keep the existing factor.
If 0 is entered, the display will advance to the next prompt (tdec).
8