Resetting the Tansceiver
If your transceiver seems to be malfunctioning, resetting
the microprocessor may solve the problem. The following 2
reset modes are available. When performing the reset, you
may lose memory data and stored information. Back up or
write down important data before performing the reset.
■ Initial Settings
The factory defaults for the operating frequencies are as
follows.
Transceiver : 410.000MHz (C), 450.000MHz (C2)
The Memory Channels have no data stored. The Call
Channel and frequency step size default values.
Note : When in Channel Display Mode or while Key Lock is
activated, you cannot perform VFO reset or Full reset.
■ Full Reset
This resets all transceiver parameters to the factory de-
fault values. There are two methods available for resetting
the transceiver.
• Full Reset Method 1:
1. With the transceiver power OFF, press [F]+[ ] (Power).
• All indicators light momentarily, followed by the full reset
confirmation message.
2. Press [F].
• "SURE ?" appears.
• Press any key other than [F] to cancel.
3. Press [F] again to reset the transceiver.
• "WAIT" appears momentarily.
• Full Reset Method 2:
1. Press [F], [MENU] and turn the Tuning control to select
Menu No. 99 (RESET).
2. Press [MENU] and turn the Tuning control to select
"FULL".
3. Press [MENU].
• "SURE ?" appears.
• Press any key other than [MENU] to cancel.
4. Press [MENU] to reset the transceiver.
• "WAIT" appears momentarily.

RESETTING THE TRANSCEIVER

■ VFO Reset
This resets the transceiver parameters excluding the
DTMF Memory, the Memory channel contents, and the Call
channel contents. There are two methods available for reset-
ting the transceiver.
Note : Menu No. 7 (P.VFO) and Menu No. 10 (OFFSET) re-
turn to the factory default values.
• VFO Reset Method 1:
1. With the transceiver power OFF, press [VFO]+[ ]
(Power).
• The VFO reset confirmation message appears.
2. Press [VFO].
• "SURE ?" appears.
• Press any key other than [VFO] to cancel.
3. Press [VFO] again to reset the transceiver.
• "WAIT" appears momentarily.
• VFO Reset Method 2:
1. Press [F], [MENU] and turn the Tuning control to select
Menu No. 99 (RESET).
2. Press [MENU] and turn the Tuning control to select
"VFO".
3. Press [MENU].
• "SURE ?" appears.
• Press any key other than [MENU] to cancel.
4. Press [MENU] to reset the transceiver.