Mitsubishi Electric PCA-RP-GA Installation Manual
Mitsubishi Electric PCA-RP-GA Installation Manual

Mitsubishi Electric PCA-RP-GA Installation Manual

Hide thumbs Also See for PCA-RP-GA:

Advertisement

Air-Conditioners
PCA-RP·GA (2)
PCH-P·GAH

INSTALLATION MANUAL

For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing
the air-conditioner unit.
INSTALLATIONSHANDBUCH
Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-
nungsanleitung und das Installationshandbuch gründlich durchlesen.
MANUEL D'INSTALLATION
Avant d'installer le climatiseur, lire attentivement ce manuel, ainsi que le manuel d'installation de l'appareil
extérieur pour une utilisation sûre et correct.
INSTALLATIEHANDLEIDING
Lees deze handleiding en de installatiehandleiding van het buitenapparaat zorgvuldig door voordat u met het
installeren van de airconditioner begint.
MANUAL DE INSTALACIÓN
Para un uso seguro y correcto, lea detalladamente este manual de instalación antes de montar la unidad de
aire acondicionado.
MANUALE DI INSTALLAZIONE
Per un uso sicuro e corretto, prima di installare il condizionatore d'aria leggere attentamente il presente
manuale ed il manuale d'installazione dell'unità esterna.
E°XEIPI¢IO O¢H°IøN E°KATA™TA™H™
°È· ÛˆÛÙ‹ Î·È ·ÛÊ·Ï‹ ¯Ú‹ÛË, ‰È·‚¿ÛÙ ÚÔÛÂÎÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ, ηıÒ˜ Î·È ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ
ÂÁηٿÛÙ·Û˘ Ù˘ Â͈ÙÂÚÈ΋˜ ÌÔÓ¿‰·˜, ÚÈÓ ·fi ÙËÓ ÂÁηٿÛÙ·ÛË Ù˘ ÌÔÓ¿‰·˜ ÎÏÈÌ·ÙÈÛÙÈÎÔ‡.
MANUAL DE INSTALAÇÃO
Para uma utilização segura e correcta, leia atentamente este manual e o manual de instalação da unidade
exterior antes de instalar o aparelho de ar condicionado.
INSTALLATIONSMANUAL
Læs af sikkerhedshensyn denne manual samt manualen til installation af udendørsenheden grundigt, før du
installerer klimaanlægget.
INSTALLATIONSMANUAL
Läs bruksanvisningen och utomhusenhetens installationshandbok noga innan luftkonditioneringen installeras så
att den används på ett säkert och korrekt sätt.
MONTAJ ELK‹TABI
Emniyetli ve do¤ru kullanım için, klima cihazını monte etmeden önce bu kılavuzu ve dıfl ünite montaj kılavuzunu
tamamıyla okuyun.
РУКОВОДСТВО ПО УСТАНОВКЕ
Для обеспечения безопасной и надлежащей эксплуатации внимательно прочтите данное руководство и
руководство по установке наружного прибора перед установкой кондиционера.
FOR INSTALLER
FÜR INSTALLATEURE
POUR L'INSTALLATEUR
VOOR DE INSTALLATEUR
PARA EL INSTALADOR
PER L'INSTALLATORE
°π∞ ∞À∆√¡ ¶√À ∫∞¡∂π ∆∏¡ ∂°∫∞∆∞™∆∞™∏
PARA O INSTALADOR
TIL INSTALLATØREN
FÖR INSTALLATÖREN
MONTÖR ‹Ç‹N
ДЛЯ УСТАНОВИТЕЛЯ
English
Deutsch
Français
Nederlands
Español
Italiano
∂ÏÏËÓÈο
Português
Dansk
Svenska
Türkçe
Русский

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric PCA-RP-GA

  • Page 1: Installation Manual

    Air-Conditioners PCA-RP·GA (2) PCH-P·GAH INSTALLATION MANUAL FOR INSTALLER English For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit. INSTALLATIONSHANDBUCH FÜR INSTALLATEURE Deutsch Aus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie- nungsanleitung und das Installationshandbuch gründlich durchlesen.
  • Page 2: Table Of Contents

    • The terminal block cover panel of the unit must be firmly attached. rectly installed unit may fall down and cause damage or injuries. • Use only accessories authorized by Mitsubishi Electric and ask a dealer or • The unit must be securely installed on a structure that can sustain its weight.
  • Page 3: Installation Location

    2. Installation location 2.1. Outline dimensions (Indoor unit) (Fig. 2-1) Select a proper position allowing the following clearances for installation and mainte- nance. (mm) Models 1000 Min. 270 Min. 300 Min. 500 Max. 250 50GA2, 60, 71 1310 Min. 270 Min.
  • Page 4: Installing The Refrigerant Piping

    3. Installing the indoor unit 3.2.4. Indoor unit preparation (Fig. 3-4) 1. Install the suspending bolts. (Procure the W3/8 or M10 bolts locally.) Predetermine the length from the ceiling (1 within 100 mm). A Ceiling surface B Suspending bolt C Suspending bracket Fig.
  • Page 5: Tions

    4. Installing the refrigerant piping 4.1.2. For devices that use R410A refrigerant • Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes.
  • Page 6: Drainage Piping Work

    5. Drainage piping work 5.1. Preparation for left side tubing installation (Fig. 5-1) A Drain pan • For left side tubing, be sure to insert the rubber plug into the right drain port. B Plug • Install the drain tubing as it slopes continuously downward. •...
  • Page 7 6. Electrical work 6.1.1. Indoor unit power supplied from outdoor unit The following connection patterns are available. The outdoor unit power supply patterns vary on models. 1:1 System A Outdoor unit power supply <For models without heater> <For models with heater> B Earth leakage breaker C Wiring circuit breaker or isolating switch D Outdoor unit...
  • Page 8: Remote Controller

    6. Electrical work Simultaneous twin/triple/four system A Outdoor unit power supply <For models without heater> B Earth leakage breaker * The optional wiring replacement kits are required. C Wiring circuit breaker or isolating switch D Outdoor unit E Indoor unit/outdoor unit connecting cords F Remote controller G Indoor unit H Option...
  • Page 9 6. Electrical work 2) Connecting procedures (Fig. 6-4) 1 Connect the remote controller cord to the terminal block. A To TB5 on the indoor unit B TB6 (No polarity) 3) Two remote controllers setting. If two remote controllers are connected, set one to “Main” and the other to “Sub”. For setting procedures, refer to “Function selection of remote controller”...
  • Page 10: Function Settings

    6. Electrical work 6.3. Function settings 6.3.1 Function setting on the unit (Selecting the unit functions) ⁄ Mode number 1) For wired remote controller (Fig. 6-8) ⁄ Setting number Changing the power voltage setting ⁄ Refrigerant address • Be sure to change the power voltage setting depending on the voltage used. ⁄...
  • Page 11: Test Run

    6. Electrical work Select unit numbers 01 to 03 or all units (AL [wired remote controller]/07 [wireless remote controller]) Mode Settings Mode no. Setting no. Initial setting Setting Filter sign 100 Hr 2500 Hr No filter sign indicator Fan speed Standard (PLH/PLA)/Silent (PCH/PCA) High ceiling 1 (PLH/PLA)/Standard (PCH/PCA) High ceiling 2 (PLH/PLA)/High ceiling (PCH/PCA)
  • Page 12 7. Test run 7.3. Self-check 7.3.1. Wired remote controller (Fig. 7-3) 1 Turn on the power. CHECK 2 Press the [CHECK] button twice. 3 Set refrigerant address with [TEMP] button if system control is used. ERROR CODE 4 Press the [ON/OFF] button to stop the self-check. TEMP.
  • Page 13 7. Test run [Output pattern B] Errors detected by unit other than indoor unit (outdoor unit, etc.) Wired remote Wireless remote controller controller Beeper sounds/OPERATION Symptom Remark INDICATOR lamp flashes Check code (Number of times) Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit) Compressor overcurrent interruption U3, U4 Open/short of outdoor unit thermistors...
  • Page 14: Easy Maintenance Function

    8. Easy maintenance function Display example (Comp discharge temperature 64°C) By using the maintenance mode, you can display many types of maintenance data on the remote controller such as the heat exchanger temperature and compressor current consumption for the indoor and outdoor units. This function can be used whether the air conditioner is operating or not.
  • Page 15 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.