Vibra circuitry

Vibra is used for Vibra alarm function.
The vibra motor is connected to AVILMA asic VibraP and VibraN pulse width modulated outputs through Filter.
Vibra is built into cover and connected via cable to plug on PWB.

AV connector

The AV Connector consists of single ended mono or stereo audio output and mono audio input.
The following table shows the AV interface electrical characteristics.
Signal
Function/
name
Parameter
HSMIC
HS mic audio
input
Page 6 –38
Figure 80 AV connector circuitry
Figure 81 Vibra circuitry
Table 10 AV interface electrical characteristics
Min
Typ
-
-
1,3
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
System Module and User Interface
Max
Unit
Vpp
Max neg level
0,7V
RM-179; RM-223