RF troubleshooting
12. Measure the power levels with a marker.
Take the first measurement from 250 us after the trigger, the second after 750 us, the third after 1220
us and so on for every 500 us until the table is filled.
High Burst pane, click Calculate.
13. In the
14. Check that the calculated values are within the limits specified in the following table:
C0-high
C1-high
C2-high
C0-mid
C1-mid
C2-mid
C0-low
C1-low
C2-low
Issue 1
Figure 42 High burst measurement
-10000
COMPANY CONFIDENTIAL
Copyright © 2007 Nokia. All rights reserved.
Min
-0.5
-50
400
-0.7
0
400
-4
-400
Max
5
50
900
0.7
50
900
4
440
15000
Page 4 –49