11-2.

EXTERNAL OUTPUT

OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
Indoor
control PC board
Communication kit
Optional parts
Operation
Indoor unit
Stop
ON
Output signal
OFF
Parts (Optional)
Parts name
External connect kit
Communication box kit
* For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire
(UTY-XWZX).
Wire (External output) : UTY-XWZX
Connector
24V DC
Ex.)Relay unit
1
V
2
*10 m
Signal
* Make the distance from the PC board to the connected unit within 10m.
Relay spec. : Max.24VDC, 10mA to less than 500mA.
Model name
UTY-XWZX
UTY-XCBXE (for AS G07/09/12LE)
UTY-XCBXZ1 (for AS G14LE)
- (01 - 24) -
Connected unit
Ex.)Display
Relay
power
supply