Dcs Rx - Samsung SGH-S501i Service Manual

Hide thumbs Also See for SGH-S501i:
Table of Contents

Advertisement

Flow Chart of Troubleshooting

9-2-2. DCS RX

Continuous RX ON
RF Input : 660 CH
AMP : -50dBm
NORMAL CONDITION
Catch the channel ?
YES
U100 Check
Pin #6 ≥ -65dBm ?
YES
U100 Check
Pin #10,11 ≥ -65dBm ?
YES
UCP100 Check
Pin#8,9 ≥ -65dBm ?
YES
UCP100 Check
Pin#34 =Clean 2.8V?
YES
UCD100 Check
Pin#35,36,37,38=100mV?
YES
Check U300
This Document can not be used without Samsung's authorization
NO
NO
NO
NO
NO
NO
UCP100 Check
Pin #21 : 13MHz ?
Vpp : 1.1V?
YES
UCP100
Change or resolder
SAMSUNG Proprietary-Contents may change without notice
Check soldered status of
L101
RFS101, C102, L103
Resoer or Change
U100 Resolder or Change
Check soldered status of
L106, L107, C109
C104
NO
R119 = 13MHz ?
Vpp : 1.2V?
YES
C127, C128
resolder
9-22
NO
R117 = 1.5V ?
YES
TCX101
Change or resolder
NO

Advertisement