Ribbonminder Host Data Stream Commands; Set Job Rate; When Worn Action - Printronix P9212 Setup Manual

Line matrix printers
Hide thumbs Also See for P9212:
Table of Contents

Advertisement

RibbonMinder Host Data Stream Commands

In addition to controlling the RibbonMinder feature from the printer's control
panel, you can also control RibbonMinder from the host computer by
sending control code sequences to the printer.
NOTE: The host commands "Set Job Rate," "When Worn Action," and
Following are brief descriptions of the host commands that control
RibbonMinder. For more information, refer to the Impact Printers
Programmer's Reference Manual.
NOTE: If your printer is set to Serial Matrix emulation, substitute ESC for

Set Job Rate

Command: SFCC r J NNNN E
where — NNNN is the JOB RATE value between 0 and 1000 expressed as a
decimal number having between one and four digits. Each individual digit of
the value is represented by the corresponding hex code. For example, if the
JOB RATE value is 341, NNNN will be the ASCII characters 3 (33 hex),
4 (34 hex), and 1 (31 hex). The control code sequence will be
CHR$(1);"rJ341E";
Examples of ASCII Hex values: 01 72 4A 33 34 31 45

When Worn Action

Command: SFCC r A x
where — the value of x determines the printer action as follows:
Examples of ASCII Hex values: 01 72 41 53
RibbonMinder
"Enable/Disable" supply values to the RibbonMinder features. For
proper operation, if you are using these commands, you must send
them to the printer prior to printing data. You can either send these
commands directly from the host computer, or you can embed them
in your print job before the print data.
the Special Function Control Character (SFCC) in the control code
sequences below.
STOP PRINTER
AUD/VIS ALARM
VISUAL ALARM
S
(Hex 53)
A
(Hex 41)
V
(Hex 56)
6–21