3 Operation
Icon
An external heat source is active. Example: Gas
burner.
The disinfection mode is active.
A malfunction occured. Press 
information about the malfunction.
Weather­dependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
INFORMATION
Quiet mode is NOT applicable for this unit.
3.3
Space heating control
3.3.1
Setting the space operation mode
About space operation modes
The heat pump is a heating only model. The system can heat up a
space, but NOT cool down a space.
3.3.2
Using the room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To switch between home pages, go
to [7.1.3]: 
 > User settings > Display > User profile.
User profile = Basic
15:20
Mon
Room
20.0°C
Actual temperature
To read out the actual and desired room temperature
1 Go to the room temperature home page (Room).
Result:  You  can  read  out  the  actual  temperature. 
20.0°C
Actual temperature
2 Press 
.
Result:  You  can  read  out  the  desired  temperature. 
22.0°C
Desired temperature
To temporarily overrule the room temperature schedule
1 Go to the room temperature home page (Room).
2 Use 
 or 
 to adjust the temperature.
To change the mode from scheduled to preset value
Prerequisite: User profile = Detailed.
1 Go to the room temperature home page (Room).
2 Press 
 or 
 to select a preset value (  or  ).
Result: The mode will return to Scheduled according to the overrule
period.
Operation manual
4
Description
 to display more
User profile = Detailed
Mon
15:20
20.0°C
Room
Actual temperature
Scheduled
Tue
17:30
To set the overrule period
1 Go to [7.2]: 
 > User settings > Temperature lock.
2 Select a value and press 
▪ Permanent
▪ hours (2, 4, 6, 8)
3.3.3
Using the leaving water temperature
home pages (main + additional)
INFORMATION
The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Example: Underfloor heating is designed for lower leaving
water  temperature  than  radiators  and  heat  pump
convectors  and/or  fan  coil  units.  You  only  have  to  adjust
leaving water temperature settings in case of problems.
For  more  information  about  the  leaving  water  temperature,  see  the
user reference guide.
3.4
Domestic hot water control
3.4.1
Reheat mode
In  reheat  mode  ( ),the  DHW  tank  continuously  heats  up  to  the
temperature  shown  on  the  DHW  tank  temperature  home  page
(example: 50°C).
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
3.4.2
Scheduled mode
In  scheduled  mode  ( ),  the  DHW  tank  produces  hot  water
corresponding  to  a  schedule.  The  best  time  to  allow  the  tank  to
produce hot water is at night, because:
▪ The space heating demand is lower
▪ Electricity tariffs are lower
Example: 
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
:
3
2
4
t
14:00
21:00
4
3
5
t
14:00
21:00
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P351750­1C – 2014.03