3 Operation
Icon
An external heat source is active. Example: Gas
burner.
The disinfection mode is active.
A malfunction occured. Press
information about the malfunction.
Weatherdependent mode is active.
User permission level = Installer.
Defrost/oil return mode is active.
Hot start mode is active.
Emergency operation is active.
INFORMATION
Quiet mode is NOT applicable for this unit.
3.3
Space heating control
3.3.1
Setting the space operation mode
About space operation modes
The heat pump is a heating only model. The system can heat up a
space, but NOT cool down a space.
3.3.2
Using the room temperature home page
Typical room temperature home pages
Depending on the user profile, the user interface gives you either a
basic or a detailed home page. To switch between home pages, go
to [7.1.3]:
> User settings > Display > User profile.
User profile = Basic
15:20
Mon
Room
20.0°C
Actual temperature
To read out the actual and desired room temperature
1 Go to the room temperature home page (Room).
Result: You can read out the actual temperature.
20.0°C
Actual temperature
2 Press
.
Result: You can read out the desired temperature.
22.0°C
Desired temperature
To temporarily overrule the room temperature schedule
1 Go to the room temperature home page (Room).
2 Use
or
to adjust the temperature.
To change the mode from scheduled to preset value
Prerequisite: User profile = Detailed.
1 Go to the room temperature home page (Room).
2 Press
or
to select a preset value ( or ).
Result: The mode will return to Scheduled according to the overrule
period.
Operation manual
4
Description
to display more
User profile = Detailed
Mon
15:20
20.0°C
Room
Actual temperature
Scheduled
Tue
17:30
To set the overrule period
1 Go to [7.2]:
> User settings > Temperature lock.
2 Select a value and press
▪ Permanent
▪ hours (2, 4, 6, 8)
3.3.3
Using the leaving water temperature
home pages (main + additional)
INFORMATION
The leaving water is the water that is sent to the heat
emitters. The desired leaving water temperature is set by
your installer in accordance with the heat emitter type.
Example: Underfloor heating is designed for lower leaving
water temperature than radiators and heat pump
convectors and/or fan coil units. You only have to adjust
leaving water temperature settings in case of problems.
For more information about the leaving water temperature, see the
user reference guide.
3.4
Domestic hot water control
3.4.1
Reheat mode
In reheat mode ( ),the DHW tank continuously heats up to the
temperature shown on the DHW tank temperature home page
(example: 50°C).
T t
1
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
3.4.2
Scheduled mode
In scheduled mode ( ), the DHW tank produces hot water
corresponding to a schedule. The best time to allow the tank to
produce hot water is at night, because:
▪ The space heating demand is lower
▪ Electricity tariffs are lower
Example:
T t
1
2
60°C
50°C
40°C
15°C
00:00
07:00
T
DHW tank temperature
t
t
Time
:
3
2
4
t
14:00
21:00
4
3
5
t
14:00
21:00
EGSQH10S18AA9W
Daikin Altherma ground source heat pump
4P3517501C – 2014.03