Error code table for service

Code
In the tray opening procedure, if opening action is not completed within 4.5 sec., the procedure moves to closing action.
Afterwards if this closing action is not completed within 4.5 sec., the procedure recalls opening action again.
L∗
This recalled opening action is not also completed within 4.5 sec., the operation halts.
In the tray closing procedure, if closing action is not completed within 4.5 sec., the procedure moves to opening action.
Afterwards if this opening action is not completed within 4.5 sec., the operation halts.
(1) When the slider moves in REV direction, and if TOC position SW does not become "H" within 3.4 sec., the operation halts.
(2) After (1) is completed normally and then the slider moves in the FWD direction, and if TOC position SW does not become "L"
E∗
within 300 msec., the operation halts.
(3) After (2) is completed normally and then the slider moves in the REV direction, and if TOC position SW does not become "H"
within 300 msec., the operation halts.
When Q data is not read in 1 sec. and ATIP data is not read in 1 sec. ,the system tries to read them for 3 times. And when even
P∗
then both Q data and ATIP data are not read, the operation halts, etc.
When reading PCA area, searching to playback starting position is failed, then even this is tried twice and the search is not
completed, the operation halts.
C∗
When writing PCA area, the rotation does not reach to the required speed at writing position, so that writing is not possible to start.
Or searching to writing starting position is failed and retried for 19 times, as a result that both are incomplete, then the operation
halts.
Once disc discrimination is completed, and focus-in action is failed, then the operation halts.
F∗
If the pick-up jump occurs during recording, and not recovered, then the operation halts.
A∗
If ATIP data is not to be read for 4 sec. during recording, then the operation halts.
If PMA writing is not completed within 60 sec., then the operation halts.
d∗
If reading of TOC and PMA is failed, or missing information is observed in read data, the error occurs.
When to start recording and RF signal exists instead at the end edge boundary of disc, the error occurs.
Generation Condition