Si Pre-Confi Guration Change - Sony Ericsson K800 Electrical Repair Manual

Hide thumbs Also See for K800:
Table of Contents

Advertisement

SI-K800/K610 Pre-confi guration change
Applicable for: K800/K790/K610/V630/K618
Information:
The Pre-confi guration process is updated on EMMA III. The Pre-confi guration can
fi x and prevent "Can not power on" problems on units made before approx. 06W42.
Please note that this update will not start until the EMMA III client is restarted!
Instruction:
Log on to EMMA III as usual. You should press "5" fi rst, keep it pressed and then
press the "2" and keep it pressed. Thereafter while pressing "2" and "5", you attach
the USB cable. When icon appears in the Service Client window, release the keys.
Previously, you've had an automatically performed Pre-confi guration, but due to
needed structural changes, there will be a question to respond to.
Select "Yes" and the Pre-confi guration will proceed as normal.
APPENDIX
SI Pre-Confi guration Change
When selecting "No", the operation will be cancelled.
There is no need at this stage to update the software if you have the latest software version
for the DPY.
IMPORTANT!
The pre-confi guration process is successful even if EMMA III states that the script failed.
MU Information:
This change is done to support a recovery script to be used in the scrap recovery centers.
(BMC will not need it since region China have not been affected by the simlock bug)
Reference number: 15195-60423
Created: 2007-03-21
Author:
Patrik Cesar (patrik.cesar@ecs.ericsson.se)
The pre-confi guration process is successful anyway.