r e a d and s aVe The se ins T ruc T ions
warning
To reduce The risk of fire, elecTric shock, or injury To
persons, oBserVe The following:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer at the address or telephone number listed in
the warranty.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. This unit must be grounded.
7. Do not connect this product as a load on a fan speed
control or light dimmer.
8. Read and understand entire instructions before proceeding
with installation.
intelligent Ventilation system
®
insTallaTion
Install controls and wire them as shown. Use following
guidelines:
• imporTanT:
QTXE080 Ultra Silent™ fan must be wired to SMSC080
QTXE110 Ultra Silent™ fan must be wired to SMSC110
• Use minimum 75 °C rated electrical wiring.
• Except for required neutral wire, these controls install
• Specify deep device electrical boxes where controls will
• All controls must be grounded using attached ground wire.
models ssQTXe080 • ssQTXe110
LINE
Black
GROUND
POWER
Bare
Copper
LINE
(GFCI
protected
if required)
NEUTRAL
White
SmartSense
control.
®
SmartSense
control.
®
like normal switches. Make sure electrician knows each
control location must have a neutral wire. Neutral wire
at switch locations may be code requirement or regular
practice in installation municipality; but unless explicitly
specified, electrician might not install it.
be installed. These controls fit in most North American
electrical boxes; however, deep boxes provide extra
working space which eases installation. Labor cost
savings can offset higher box costs, which is usually
less than a dollar over standard depth boxes. Use boxes
that have 18 cu. in. minimum volume and are at least
1-1/2 in. deep.
Page 
LINE
Black
GROUND
Bare
CONTROL
Copper
LOAD
Red
NEUTRAL
White
WHITE
BLACK
GROUND
Green
FAN

Advertisement

loading

Summary of Contents for Broan ssQTXe080

  • Page 1 Labor cost savings can offset higher box costs, which is usually less than a dollar over standard depth boxes. Use boxes that have 18 cu. in. minimum volume and are at least 1-1/2 in. deep. • All controls must be grounded using attached ground wire. models ssQTXe080 • ssQTXe110 LINE Black LINE Black GROUND GROUND Bare...
  • Page 2: Control Operation

    Multiple installations communicate through a home’s electrical power circuits to form an indoor air quality network. Communication pathways are called links. A phase coupler models ssQTXe080 • ssQTXe110 is required if multiple installations are connected to both electrical power phases. Individual systems in a multiple installation home can operate independently; although, it is recommended to link multiple installations as an indoor air quality network. if a...
  • Page 3 When Master control is put in Disabled mode, it will not turn on any fans for automatic ventilation and recommended indoor air quality ventilation level is not assured. Manual control fan operation is not affected. Vacation Mode 1. Put Master control in Program mode; press and hold SET button for 3-seconds and then release it. models ssQTXe080 • ssQTXe110 TaBle a floor area (ft 0 - 1 2 - 3 < 1500 1501 - 3000 3001 - 4500...
  • Page 4: Warranty

    Broan-Nutone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. tHeRe ARe NO OtHeR WARRANtIeS, eXPReSS OR IMPLIeD, INCLuDING, But NOt LIMIteD tO, IMPLIeD WARRANtIeS OF MeRCHANtABILItY OR FItNeSS FOR A PARtICuLAR PuRPOSe.
  • Page 5: Instalación

    Acondicionado (American Society for Heating, Refrigeration and Air Conditioning Engineers, ASHRAE) y las autoridades normativas locales. 5. Al cortar o perforar a través de la pared o del techo, tenga cuidado de no dañar el cableado eléctrico ni otros servicios ocultos. 6. Esta unidad debe conectarse a tierra. 7. No conecte este producto como carga de un control de velocidad de un ventilador o de un reductor de intensidad de luz. 8. Lea y entienda todas las instrucciones antes de continuar con la instalación. modelos ssQTXe080 • ssQTXe110 de Broan ® insTalaciÓn LÍNEA Negro TIERRA TIERRA Cobre LÍNEA DE...
  • Page 6 índices de ventilación en viviendas grandes; no obstante, se recomienda usar instalaciones múltiples en viviendas con varios baños. Las instalaciones múltiples suministran una ventilación distribuida por toda la vivienda. modelos ssQTXe080 • ssQTXe110 Las instalaciones múltiples se comunican a través de los circuitos eléctricos de la vivienda, para formar una red de calidad de aire bajo techo. Las rutas de comunicación se conocen como enlaces. Se requiere un acoplador de fase si se conectan instalaciones múltiples en ambas fases de la energía eléctrica.
  • Page 7 Modo de vacaciones 1. Ponga el control maestro en modo de programa; presione y sostenga el botón SET durante 3 segundos y luego suéltelo. 2. El LED debe encenderse y apagarse cada segundo (destello lento); si no, entonces repita el paso 1. modelos ssQTXe080 • ssQTXe110 Área del piso (pies < 1500 1501 - 3000 3001 - 4500...
  • Page 8 Para calificar para servicio bajo esta garantía, usted debe (a) notificar a Broan-Nutone en la dirección o al teléfono abajo, (b) dar el número de modelo y la identificación de pieza y (c) describir el defecto en el producto o pieza.

This manual is also suitable for:

Ssqtxe110Sqtxe080Smartsense ssqtxe110Smartsense ssqtxe080